MétaCan
Menu
Back to cohort
Record W1971694051 · doi:10.1002/rcm.2181

Porous polymer monolith assisted electrospray from a glass microdevice

2005· article· en· W1971694051 on OpenAlexafffund
Terry Koerner, Richard D. Oleschuk

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2005
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsQueen's University
FundersNatural Sciences and Engineering Research Council of CanadaGenome Prairie
KeywordsChemistryMonolithElectrosprayCommon emitterAnalytical Chemistry (journal)Capillary actionMicrofluidicsPolymerSeal (emblem)Detection limitEtching (microfabrication)RepeatabilityChromatographyMass spectrometryNanotechnologyOptoelectronicsComposite materialMaterials science

Abstract

fetched live from OpenAlex

The coupling of a lab-on-a-chip microfluidic device to a nanoelectrospray ionization mass spectrometer has the potential to automate many routine analytical procedures and produce a powerful analytical tool. However, past coupling strategies have relied on complex manufacturing steps including drilling and etching the device to attach a capillary or building a nanospray emitter directly into the device. This study shows that a nanospray emitter can be easily fabricated using a porous polymer monolith (PPM) at the end of a glass microdevice. These devices are able to obtain a stable electrospray at a variety of flow rates (50-500 nL/min) but optimal results are obtained at lower flow rates (50-100 nL/min) compatible with electroosmotic flow processes. The PPM is photo-patterned so that it can be placed in any position within the channel of the device with no dead volume. The porous character and the hydrophobic nature of the PPM both aid in development of a stable electrospray process. Total ion current traces for the constant infusion of leucine-enkephalin and PPG show relative standard errors as low as 4%, and produce mass spectra with good signal-to-noise (S/N 43) from only 2 fmol of material. In addition, multiple experiments in a given day show good repeatability with variability as low as 13%, and the multiple flow paths inherent in the PPM limit sprayer clogging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.233
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207