MétaCan
Menu
Back to cohort
Record W1972078733 · doi:10.1021/ja053417j

Direct Molecular Detection of Nucleic Acids by Fluorescence Signal Amplification

2005· article· en· W1972078733 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of the American Chemical Society · 2005
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced biosensing and bioanalysis techniques
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsChemistryNucleic acidDNAFluorescencePolythiopheneFörster resonance energy transferBiosensorCationic polymerizationBiophysicsCombinatorial chemistryBiochemistryPolymerOrganic chemistryConductive polymer

Abstract

fetched live from OpenAlex

An integrated PCR-free DNA sensor, which combines a sequence-specific receptor, an optical polymeric transducer, and an intrinsic fluorescence amplification mechanism, is reported. This sensor is based on the different conformations adopted by a cationic polythiophene when electrostatically bound to ss-DNA or ds-DNA, and on the efficient and fast energy transfer between the resulting fluorescent polythiophene/ds-DNA complex and neighboring fluorophores attached to ss-DNA probes. This molecular system allows the detection of only five molecules in 3 mL of an aqueous solution, or 3 zM, in 5 min. Moreover, this work demonstrates, for the first time, the direct detection of single nucleotide polymorphisms (SNPs) from clinical samples in only a few minutes, without the need for nucleic acid amplification.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.267

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.244
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it