MétaCan
Menu
Back to cohort
Record W1972643853 · doi:10.1243/09576509jpe897

Exergy analysis of a gas turbine trigeneration system using the Brayton refrigeration cycle for inlet air cooling

2010· article· en· W1972643853 on OpenAlexaff
Abdul Khaliq, Keshavendra Choudhary, İbrahim Dinçer

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy · 2010
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsOntario Tech University
Fundersnot available
KeywordsExergyBrayton cycleExergy efficiencyOverall pressure ratioGas compressorInletEnvironmental scienceCombined cycleRefrigerationAir coolingNuclear engineeringTurbineMechanical engineeringProcess engineeringEngineering

Abstract

fetched live from OpenAlex

Trigeneration with gas turbines as prime mover can improve energy utilization efficiency significantly because of their potential of high economic and energy saving characteristic. In this article, a novel method for compressor inlet air cooling in gas turbine trigeneration is achieved by the Brayton refrigeration cycle driven by the gas turbine and air is used as a working fluid. Introducing the air refrigeration cycle for inlet air cooling provides the advantage of quite low temperatures close to 0 ° C and even lower, and enhances the performance significantly. The performance was evaluated by both energy and exergy efficiencies, with the latter providing good guidance for system improvement. The influences of key parameters, which include extraction pressure ratio, extraction mass rate, turbine inlet temperature (TIT), process heat pressure, and ambient relative humidity on the cycle performance parameters, have been investigated. It is found that the inlet air-cooled gas turbine trigeneration cycle has a good thermal performance, with first and second law efficiencies of 91 per cent and 55 per cent, respectively, for the base case studied (having a maximum cycle temperature of 1327 ° C). For a minimum process heat pressure of 4 bar, the energy and exergy efficiencies were obtained as 89 per cent and 51 per cent, respectively. Gas turbine trigeneration plants with and without inlet air cooled by the Brayton refrigeration cycle are compared with each other, and the effect of inlet air cooling on energy and exergy efficiencies is clarified. Inlet air cooling increases the energy and exergy efficiencies and decreases the electrical to thermal energy ratio significantly. Exergy analysis indicates that maximum exergy is destroyed during combustion and steam generation, which represents around 65 per cent of the total exergy destruction in the overall system. The exergy destruction in major components of trigeneration varies significantly with TIT and process heat pressure. The present analysis provides further information on the role of inlet air cooling through extracted mass rate influence on the performance of a gas turbine-based trigeneration system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.357
Threshold uncertainty score0.366

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.210
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part A Journal of Power and EnergySame topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207