MétaCan
Menu
Back to cohort

Out-of-plane microvalves for whole blood separation on lab-on-a-CD

2010· article· en· W1972998830 on OpenAlexafffund
Tingjie Li, Limin Zhang, Kar Man Leung, Jun Yang

Bibliographic record

VenueJournal of Micromechanics and Microengineering · 2010
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsWhole bloodMicrofluidicsPlasmaMaterials scienceBiomedical engineeringOptoelectronicsNanotechnologyEngineeringPhysicsSurgery

Abstract

fetched live from OpenAlex

The emergence of lab-on-a-CD technology provides a centrifugal and compact platform for high throughput blood analysis in point-of-care (POC) diagnostics. Blood separation of the whole blood is the first step for clinical blood diagnosis. This paper describes a novel design of an out-of-plane microvalve that enables high performance of whole blood separation on lab-on-a-CD centrifugal devices. In our lab-on-a-CD design, blood cells and plasma are redistributed into a downstream sedimentation reservoir and an upstream supernatant reservoir, respectively, when the device spins. By tuning the rotational speed, the ‘close’ or ‘open’ status of an out-of-plane microvalve embedded in the lab-on-a-CD device is controlled to isolate these two reservoirs. Compared with a similar design but without the out-of-plane microvalve, this novel microvalve structure can effectively prevent blood cells from diffusing back to the supernatant reservoir containing pure plasma, and thus improve the performance of blood separation as well as subsequent blood analysis. We demonstrate that the lab-on-a-CD device with out-of-plane microvalves can achieve 99.9% plasma purity and 96 ± 0.5% plasma yield for the whole blood. Because of its simple structure and easily controlled working mechanism, the out-of-plane microvalve not only leads to high performance of whole blood separation, but also makes the manufacturing of this type of lab-on-a-CD device easy and inexpensive. If integrated into some existing lab-on-a-CD devices, the out-of-plane microvalve may also help improve their performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.215
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Micromechanics and MicroengineeringSame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207