MétaCan
Menu
Back to cohort
Record W1975815447 · doi:10.1118/1.3157105

Development of a scatter correction technique and its application to HDR I192r multicatheter breast brachytherapy

2009· article· en· W1975815447 on OpenAlexafffund
Emily Poon, Frank Verhaegen

Bibliographic record

VenueMedical Physics · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University
FundersCanadian Institutes of Health Research
KeywordsImaging phantomBrachytherapyDosimetryNuclear medicineMonte Carlo methodMedicinePhysicsMathematicsRadiation therapyRadiology

Abstract

fetched live from OpenAlex

This article introduces a scatter correction (SC) technique for high-dose-rate (HDR) 192Ir brachytherapy dose calculations in the absence of a full scatter environment near the skin. The technique uses dosimetry data derived by Monte Carlo (MC) simulations for the Nucletron microSelectron v2 HDR 192Ir source. The data include the primary and scatter components of the radial dose function and the anisotropy function in addition to a SC table. The dose to a point of interest for each dwell position is estimated by first calculating the primary and scatter doses in an infinite water phantom. The scatter dose is then scaled by a SC factor that depends on the distances between the point of interest, the dwell positions, and the body contour of the patient. SC calculations in water phantoms of three different shapes, as well as computed tomography-based geometries of 18 multicatheter breast patients, are compared with Task Group 43 (TG-43) and PTRAN_CT MC calculations. The SC calculations show improvement over TG-43 for all test cases while taking 50% longer to run. The target and skin doses for the breast patient plans are unaffected by tissue inhomogeneities, as indicated by an agreement better than 1% between the SC and MC results. On average, TG-43 overestimates the target coverage by 2% and the dose to the hottest 0.1 cm3 (D0.1 cc) of the skin by 5%. The low-density lung causes the lung and heart D0.1 cc to differ by up to 3% for the SC method and by 2%-5% for TG-43 compared with MC calculations. The SC technique is suitable for HDR 192Ir dose calculations near the skin provided that the dose is nearly unperturbed by internal inhomogeneities. It has been validated for multicatheter breast brachytherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.929
Threshold uncertainty score0.472

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.279
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207