MétaCan
Menu
Back to cohort
Record W1976389269 · doi:10.1002/mrm.20591

Modeling and suppression of respiration‐related physiological noise in echo‐planar functional magnetic resonance imaging using global and one‐dimensional navigator echo correction

2005· article· en· W1976389269 on OpenAlexaff
Robert Barry, Ravi S. Menon

Bibliographic record

VenueMagnetic Resonance in Medicine · 2005
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsRobarts Clinical TrialsWestern University
FundersNational Institute of Biomedical Imaging and Bioengineering
KeywordsCommunication noiseNoise (video)Echo (communications protocol)Functional magnetic resonance imagingEcho-planar imagingNuclear magnetic resonanceMagnetic resonance imagingPhysicsIntensity (physics)Magnetic fieldAcousticsComputer scienceOpticsArtificial intelligenceNeuroscienceImage (mathematics)Medicine

Abstract

fetched live from OpenAlex

A major source of noise in functional magnetic resonance imaging (fMRI) arises from modulations in the local magnetic field in the head due to motion of the subject's chest through the respiratory cycle, and this physiologic noise can nullify the gains in statistical power expected by the use of higher magnetic fields for fMRI. In particular, fMRI data acquired using echo-planar imaging (EPI) are very sensitive to these spatially and temporally varying respiration-induced frequency offsets. In this study, accurate 3D magnetic field maps in the head were measured and used to determine the frequency offsets at the two extremes of the respiratory cycle. From these maps, spatially dependent frequency variations from about -1.0 Hz to +1.5 Hz were measured in the brain through the respiratory cycle. Simulations of a typical axial EPI fMRI experiment acquired in the presence of this measured field variation were performed, demonstrating regional image intensity variations between 1 and 5% in single pixel time series. The inadequacy of either global or 1D navigator echo corrections to measure and suppress respiratory-induced noise in fMRI time series is demonstrated. The nature of the spatial variations observed suggests that 2D approaches should be considered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.706
Threshold uncertainty score0.747

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.309
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207