MétaCan
Menu
Back to cohort
Record W1976510700 · doi:10.1002/jbm.a.31554

Nonfouling biomaterials based on polyethylene oxide‐containing amphiphilic triblock copolymers as surface modifying additives: Protein adsorption on PEO‐copolymer/polyurethane blends

2007· article· en· W1976510700 on OpenAlexaff
J. S. Tan, W. Glenn McClung, John L. Brash

Bibliographic record

VenueJournal of Biomedical Materials Research Part A · 2007
Typearticle
Languageen
FieldMaterials Science
TopicPolymer Surface Interaction Studies
Canadian institutionsMcMaster University
Fundersnot available
KeywordsCopolymerMaterials scienceAdsorptionChemical engineeringPolyurethaneProtein adsorptionAmphiphilePolymer chemistryLysozymePolymer blendPolymerComposite materialOrganic chemistryChemistry

Abstract

fetched live from OpenAlex

Surface modification of a segmented polyurethane was achieved by blending with novel PEO-containing amphiphilic triblock copolymers (PEO-polyurethane-PEO). Three copolymers having different PEO MW (550, 2000, 5000) were used as surface modification additives. The protein resistance of the blend surfaces was evaluated using radiolabeling methods. On the blends of copolymers with PEO blocks of MW 2000 and 5000, fibrinogen adsorption from physiologic buffer decreased with increasing copolymer content up to 20 wt%. On the blends with PEO blocks of MW 550, resistance to adsorption for a given copolymer content was much greater. For all three blend types at 20% copolymer content, reductions in adsorption compared to the unmodified PU matrix were greater than 95%. Reductions in adsorption were similar for the 20% blends and surfaces prepared by coating the copolymers directly on the matrix, suggesting that the 20% blend surfaces were completely covered by copolymer. At low copolymer content (< or =10 wt %), fibrinogen adsorption decreased with decreasing PEO block length. This was probably due to increasing surface coverage of the copolymers with decreasing block length. It is therefore concluded that surface density of PEO is more important than PEO MW for the protein resistance of these surfaces. Lysozyme, a much smaller protein, showed adsorption trends similar to fibrinogen. The adsorption of fibrinogen and lysozyme from binary solutions to blends of the copolymer with PEO blocks of 2000 MW was investigated to probe the effects of protein size on adsorption resistance. Fibrinogen and lysozyme showed similar fractional decreases in adsorption relative to the PU matrix independent of the surface density of PEO. However lysozyme was enriched in the surface relative to the solution, that is, it was adsorbed preferentially to fibrinogen.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0180.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.387
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part ASame topicPolymer Surface Interaction StudiesFrench-language works237,207