MétaCan
Menu
Back to cohort
Record W1976520399 · doi:10.1117/12.713053

Light dosimetry for low-level laser therapy: accounting for differences in tissue and depth

2007· article· en· W1976520399 on OpenAlexaff
Robert Weersink, Roger White, Lothar Lilge

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2007
Typearticle
Languageen
FieldMedicine
TopicLaser Applications in Dentistry and Medicine
Canadian institutionsOntario Institute for Cancer ResearchUniversity Health Network
Fundersnot available
KeywordsDosimetryOpticsMaterials scienceFluenceBiomedical engineeringLight therapyLaserPhotothermal therapyLow level laser therapyMonte Carlo methodNuclear medicineMedical physicsMedicineLaser therapyPhysicsMathematics

Abstract

fetched live from OpenAlex

While Low-level Light Therapy (LLLT) has demonstrated efficacy for certain indications, some aspects of the technology are still controversial. Clinical studies on LLLT range from low quality anecdotal studies to blinded, randomized, control clinical studies. These have used a variety of wavelengths, optical powers and variations in other laser parameters. While these studies show a large range in treatment outcome, comparison of treatment efficacy between these studies with respect to light dose is all but impossible since the light dose characterization in the LLLT field has not been properly defined and is not standardized. Surface irradiance is typically used in the LLLT field as the light dose parameter, ignoring factors such as tissue optical properties, beam divergence, pulsing of the source and tissue thickness to the organ or joint of interest. Drawing on experience with light dosimetry for photodynamic and photothermal therapy, we will provide an overview of light transport and dosimetry in tissue and its implications for LLLT dosimetry. In particular, we suggest that the proper measure of dose is the light fluence rate delivered to the organ or tissue of interest, usually several millimeters below the tissue surface. We have developed a technique that provides an estimate of the subsurface fluence rate based on the diffuse reflectance measured at the tissue surface. Using Monte Carlo simulations and measurements on tissue simulating phantoms, we demonstrate that this technique can be used to predict the subsurface fluence rate to within 30% of the actual value at 3-10 mm below the tissue surface.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.275
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicLaser Applications in Dentistry and MedicineFrench-language works237,207