MétaCan
Menu
Back to cohort
Record W1976774962 · doi:10.1097/opx.0b013e31818e8ad6

Imaging Protein Deposits on Contact Lens Materials

2008· article· en· W1976774962 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueOptometry and Vision Science · 2008
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
FundersNational Research Council CanadaCanada Foundation for Innovation
KeywordsLysozymeContact lensMaterials scienceMonolayerLens (geology)Scanning electron microscopeMethacrylate(Hydroxyethyl)methacrylateContact angleSilicone hydrogelChemical engineeringAtomic force microscopyDeposition (geology)SiliconeChemistryNanotechnologyBiomedical engineeringOpticsComposite materialPolymerCopolymerBiochemistry

Abstract

fetched live from OpenAlex

PURPOSE: The majority of studies investigating protein deposition on contact lens materials require that the deposit of interest be removed, potentially resulting in erroneous results if some proteins are not removed adequately. The purpose of this study was to investigate the use of in situ imaging methods to examine protein deposition on conventional poly(2-hydroxyethyl methacrylate) (polyHEMA)-based and silicone hydrogel contact lens materials. METHODS: Six silicone hydrogel and five polyHEMA-based hydrogel contact lens materials were examined by Atomic Force Microscopy (AFM) and/or Scanning Electron Microscopy (SEM) techniques, after being deposited with proteins in an in vitro model. AFM studies examined lenses deposited solely with lysozyme at approximate physiological concentrations and SEM studies were conducted on lenses exposed to a dilute mixture of lysozyme and albumin-conjugated gold spheres. RESULTS: AFM studies demonstrated that the lens materials had markedly differing surface topographies. SEM results showed that galyfilcon A and balafilcon A lenses deposited both lysozyme and albumin in relatively large aggregates, as compared with lotrafilcon A and B, in which the proteins were deposited in a more evenly spread, monolayer formation. Polymacon lenses deposited more protein than any of the silicone hydrogel materials and much of the protein was aggregated together. AFM data indicated that balafilcon A, lotrafilcon A and polymacon deposited lysozyme in a similar manner, with very little lysozyme being deposited in discrete areas. Galyfilcon A behaved very differently, with the lysozyme exhibiting both aggregates as well as string-like formations over the lens surface. CONCLUSIONS: Imaging techniques that allow proteins to be examined in situ show much promise for determining the extent and physical characterization of protein on contact lens materials. These techniques indicate that the pattern of deposition of proteins onto silicone hydrogel contact lens materials differs between materials, depending upon their bulk and surface composition.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.303
Threshold uncertainty score0.307

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.371
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it