MétaCan
Menu
Back to cohort
Record W1976875375 · doi:10.1088/0031-9155/45/5/313

Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

2000· article· en· W1976875375 on OpenAlexafffund
Seemantini K. Nadkarni, Derek R. Boughner, Maria Drangova, Aaron Fenster

Bibliographic record

VenuePhysics in Medicine and Biology · 2000
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Function and Risk Factors
Canadian institutionsLondon Health Sciences CentreRobarts Clinical TrialsWestern University
FundersMedical Research CouncilNatural Sciences and Engineering Research Council of CanadaLondon Health Sciences Centre
KeywordsVentricular volumeVolume (thermodynamics)MedicineCardiologyGold standard (test)Nuclear medicineInternal medicineRadiologyPhysicsEjection fractionHeart failure

Abstract

fetched live from OpenAlex

Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEMinter = 13.5%, %SEMintra = 11.4%, and for 2D echocardiography was %SEMinter = 21.5%, %SEMintra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.019
metaresearch head score (Gemma)0.047
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.102

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0190.047
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.325
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2000
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicCardiovascular Function and Risk FactorsFrench-language works237,207