MétaCan
Menu
Back to cohort
Record W1976927168 · doi:10.1117/12.842533

High repetition rate passively Q-switched fiber and microchip lasers for optical resolution photoacoustic imaging

2010· article· en· W1976927168 on OpenAlexafffund
Wei Shi, Ilya Utkin, Janaka C. Ranasinghesagara, Lei Pan, Yogesh Godwal, S. Kerr, Roger J. Zemp, R. Fedosejevs

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2010
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of Alberta
FundersTerry Fox Foundation
KeywordsMaterials sciencePhotoacoustic imaging in biomedicineLaserFiber laserOpticsRepetition (rhetorical device)OptoelectronicsOptical fiberResolution (logic)Photoacoustic effectComputer sciencePhysics

Abstract

fetched live from OpenAlex

Optical-resolution photoacoustic microscopy is a novel imaging technology for visualizing optically-absorbing superficial structures in vivo with lateral spatial resolution determined by optical focusing rather than acoustic detection. Since scanning of the illumination spot is required, the imaging speed is limited by the scanning speed and the laser pulse repetition rate. Unfortunately, lasers with high-repetition rate and suitable pulse durations and energies are difficult to find. We are developing compact laser sources for this application. Passively Q-switched fiber and microchip lasers with pulse repetition rates up to 300 kHz are demonstrated. Using a diode-pumped microchip laser fiber-coupled to a large mode-area Yb-doped fiber amplifier we obtained 60μJ 1-ns pulses at the frequency-doubled 532-nm wavelength. The pulse-repetition rate was determined by the power of the microchip laser pump source at 808nm and may exceed 10 kHz. Additionally, a passively Q-switched fiber laser utilizing a Yb-doped double-cladding fiber and an external saturable absorber has shown to produce 250ns pulses at repetition rates of 100-300 KHz. A photoacoustic probe enabling flexible scanning of the focused output of these lasers consisted of a 45-degree glass prism in an optical index-matching fluid. Photoacoustic signals exiting the sample are deflected by the prism to an ultrasound transducer. Phantom studies with a 7.5-micron carbon fiber demonstrate the ability to image with optical rather than acoustic resolution. We believe that the high pulse-repetition rates and the potentially compact and fiber-coupled nature of these lasers will prove important for clinical imaging applications where realtime imaging performance is essential.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.204
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207