MétaCan
Menu
Back to cohort
Record W1976931371 · doi:10.1088/0031-9155/53/3/005

Investigation of an efficient source design for Cobalt-60-based tomotherapy using EGSnrc Monte Carlo simulations

2008· article· en· W1976931371 on OpenAlexaff
Chandra P. Joshi, Johnson Darko, P B Vidyasagar, L J Schreiner

Bibliographic record

VenuePhysics in Medicine and Biology · 2008
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsKingston General HospitalQueen's University
Fundersnot available
KeywordsTomotherapyCollimatorMonte Carlo methodParallelepipedOpticsPhysicsKermaIsotropyRadioactive sourceBeam (structure)Computer scienceGeometryComputational physicsDosimetryNuclear medicineDetectorMathematicsRadiation therapyStatistics

Abstract

fetched live from OpenAlex

Recent investigations demonstrate a strong potential for Cobalt-60 (Co-60)-based tomotherapy. Reported work suggests that Co-60-based tomotherapy offers a clinically and commercially viable alternative to megavoltage x-ray-based tomotherapy. Tomotherapy applications use a combination of intensity-modulated fan beams to deliver highly conformal radiotherapy. However, conventional Co-60 units are designed to give large uniform rectangular fields using an isotropic radioactive source in a cylindrical geometry. Such cylindrical source geometry likely provides a sub-optimal use of the radioactivity within the source volume for tomotherapy applications due to a significant loss of radiated energy outside the fan beam collimation system. To investigate a more efficient source geometry suitable for Co-60 tomotherapy applications, a computer code was written to model an isotropic source in a 6-faced polyhedron geometry such as cube, parallelepiped, prism and truncated pyramid. This code was integrated with the existing EGSnrc/BEAMnrc Monte Carlo (MC) code. The integrated source code was thoroughly tested, validated and used to investigate the energy spectra, radiation output and self-shielding properties of various rectangular-shaped (RS) Co-60 sources. Fan beam dose profiles were calculated for various cylindrical and RS Co-60 sources for a range of source-to-axis distances (SAD), multi-leaf collimator-to-isocentre distances (CID) and modified collimator systems. Fringe and penumbra distances were analysed for the simulated dose profiles. Our results demonstrate that clinically acceptable fringe and penumbra distances can be achieved by a careful selection of SAD, CID, source shape and dimensions and modified collimator system. Significant overall gain in radiation output of the 20 x 1 cm(2) fan beams can be achieved by an optimal selection of the source geometry for a given active volume of Co-60. The overall gain includes the effects of change in packing density (accounting for self-absorption) and change in source shape.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.231
GPT teacher head0.404
Teacher spread0.173 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2008
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207