MétaCan
Menu
Back to cohort

Evaluation of a New Heparin Agent in Percutaneous Coronary Intervention

2010· article· en· W1978092152 on OpenAlexaffabout
Sunil V. Rao, Chiara Melloni, Shelley Myles-DiMauro, Samuel Broderick, Andrzej S. Kosinski, Neal S. Kleiman, Vladimír Džavík, Jean François Tanguay, Harish Chandna, Roger Gammon, Ernesto Rivera, John H. Alexander, Ian Fier, James Roach, Richard C. Becker

Bibliographic record

VenueCirculation · 2010
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsToronto General HospitalMontreal Heart InstituteUniversity Health Network
Fundersnot available
KeywordsMedicinePercutaneous coronary interventionHeparinMyocardial infarctionInternal medicineProtamine sulfateClinical endpointRandomized controlled trialLow molecular weight heparinCardiologyAnesthesiaSurgeryProtamine

Abstract

fetched live from OpenAlex

BACKGROUND: Factor Xa and factor IIa (thrombin) play roles in thrombotic complications after percutaneous coronary intervention. M118 is a novel low-molecular-weight heparin that has been rationally designed to capture the desired attributes of unfractionated heparin (UFH) and low-molecular-weight heparin: Potent activity against factor Xa and IIa, predictable pharmacokinetics after both intravenous and subcutaneous administration, ability to be monitored by use of point-of-care coagulation assays, and reversibility with protamine sulfate. We performed a phase 2 randomized trial to evaluate the safety and feasibility of M118 in the setting of elective percutaneous coronary intervention. METHODS AND RESULTS: Overall, 503 patients undergoing elective percutaneous coronary intervention at 43 centers in the United States and Canada were randomized in an open-label fashion to 1 of 4 arms: UFH 70 U/kg, M118 50 IU/kg IV, M118 75 IU/kg IV, or M118 100 IU/kg IV. The primary outcome was the composite of death, myocardial infarction, repeat revascularization, stroke, thrombocytopenia, catheter thrombus, bailout use of glycoprotein IIb/IIIa inhibitor, or any bleeding through 30 days. The primary end point occurred in 31.1% of patients randomized to UFH and in 22.7%, 28.3%, and 30.1% of patients randomized to M118 50, 75, and 100 IU/kg, respectively. The primary analysis comparing the rates of the primary end points between the pooled M118 groups versus UFH demonstrated that M118 was noninferior to UFH at preventing percutaneous coronary intervention-related complications (28.4% pooled M118 arms versus 31.1% UFH). The adverse event profiles of M118 and UFH were comparable. CONCLUSIONS: This phase 2 randomized trial demonstrates that M118 is well tolerated and feasible to use as an anticoagulant in patients undergoing elective percutaneous coronary intervention and forms the basis for further investigation of this agent in ischemic heart disease. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00543400.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.670
Threshold uncertainty score0.849

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.075
GPT teacher head0.382
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueCirculationSame topicAcute Myocardial Infarction ResearchFrench-language works237,207