MétaCan
Menu
Back to cohort
Record W1978936794 · doi:10.1118/1.3041167

Error analysis of marker‐based object localization using a single‐plane XRII

2008· article· en· W1978936794 on OpenAlexafffund
Damiaan F. Habets, Steven I. Pollmann, Xunhua Yuan, Terry M. Peters, David W. Holdsworth

Bibliographic record

VenueMedical Physics · 2008
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsWestern University
FundersCanadian Institutes of Health Research
KeywordsFluoroscopyComputer visionImage intensifierArtificial intelligenceDigital radiographyComputer scienceProjection (relational algebra)Medical imagingRadiographyRange (aeronautics)PhysicsOpticsAlgorithmMedicineRadiology

Abstract

fetched live from OpenAlex

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate-over a clinically practical range-the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions (+/- 0.035 mm) and mechanical C-arm shift (+/- 0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than +/- 1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than +/- 0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than +/- 1.2 mm. The tracking precision was +/- 0.65 mm for the out-of-plane translations, +/- 0.05 mm for in-plane translations, and +/- 0.05 degrees for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.829
Threshold uncertainty score0.454

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.252
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207