MétaCan
Menu
Back to cohort
Record W1979088370 · doi:10.1002/jbm.a.31369

<i>In‐vitro</i> assays of polymer‐coated stents eluting platelet glycoprotein IIb/IIIa receptor monoclonal antibody

2007· article· en· W1979088370 on OpenAlexaff
Tieying Yin, Guixue Wang, Changgeng Ruan, Randolph Guzman, Robert Guidoin

Bibliographic record

VenueJournal of Biomedical Materials Research Part A · 2007
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsSt. Boniface HospitalUniversité Laval
Fundersnot available
KeywordsMonoclonal antibodyMaterials sciencePlateletRestenosisAntithromboticPlatelet activationPolylactic acidPlatelet membrane glycoproteinMedicineStentAntibodyBiomedical engineeringPharmacologyImmunologyInternal medicinePolymer

Abstract

fetched live from OpenAlex

The monoclonal antibody (mAb) to the platelet glycoprotein (GP) IIb/IIIa receptor has potent antiplatelet and antithrombotic characteristics shown to reduce thrombus-related major complications after coronary angioplasty. This mAb can be incorporated in drug-eluting stents capable of releasing single or multiple bioactive agents into the bloodstream and surrounding tissues. Stents eluting the monoclonal mouse anti-human platelet glycoprotein IIb/IIIa antibody SZ-262 were tested for their effectiveness in improving the blood compatibility and the antithrombotic characteristics by immunofluorescence and scanning electron microscopy (SEM). The SEM results convincingly demonstrated that the surface of the mAb eluting-stents was completely free of platelet uptake without any sign of cellular debris or proteinaceous deposits, compared with controls. The deformation index of platelets on the L-polylactic acid (L-PLA) coated stents were higher than bare Nitinol intravascular stents, as shown by SEM images. Monoclonal antibody to the platelet GP IIb/IIIa receptor, when eluting from L-PLA polymer-coated stents, effectively inhibits platelet aggregation in the stent microenvironment, thus demonstrating a potential capacity of reducing thrombosis, improving blood flow and arterial patency rates, and inhibiting cyclic blood flow variations. These results highlight the possibility of such monoclonal antibody-eluting stents to reduce or possibly eliminate thrombosis and in-stent restenosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.407
Teacher spread0.354 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part ASame topicCoronary Interventions and DiagnosticsFrench-language works237,207