MétaCan
Menu
Back to cohort
Record W1980084966 · doi:10.1117/12.542107

Accurate strain measurements with fiber Bragg grating sensors and wavelength references

2004· article· en· W1980084966 on OpenAlexaff
Evangeline Rivera, D. J. Thomson

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2004
Typearticle
Languageen
FieldEngineering
TopicAdvanced Fiber Optic Sensors
Canadian institutionsUniversity of Manitoba
Fundersnot available
KeywordsFabry–Pérot interferometerFiber Bragg gratingOpticsWavelengthMaterials scienceLaserGratingOptical fiberFiber optic sensorPhysics

Abstract

fetched live from OpenAlex

Fiber Bragg grating sensors are one of many fiber optic sensor technologies that are currently being used in structural health monitoring systems. The sensors operate by detecting shif in the wavelength of relfected maxima due to applied strain. This paper studies a new fiber Bragg interrogation method that utilizes a swept wavelength laser in combination with wavelength references. These include a gas cell, which is used as the long term wavelength standard and an etalon used for accurate interpolation of peak wavelengths. An etalon is essentially a filter that has a periodic response over a broad wavelength range. Since its wavelength response spacing is smaller than the gas cell, it can be used to determine the intermediate wavelengths between two gas cell absorption lines. Peak location is a key element of this interogation method and several detection algorithms are investigated. It was determined that polynomial peak fitting is the most computationally efficient method and yields a resolution of better than 0.5 pm with signal to noise ratios of 30:1 or better. With higher signal to noise ratios, polynomial peak fitting can yield a resolution of better than 0.25 pm and a resolution of bettern than 0.25 pm. Using a tunable laser, a HCN gas cell and an etalon with maxima every 140 pm, static load tests will demonstrate that a resolution of 1 pm and an accuracy of less than 5pm can be achieved. Also, this accuracy will be maintained over a long period of time as it is based on absorption lines in the gas cell. The results of this study demonstrate that absolute accurate strain measurements can be obtained with the use of wavelength references in conjunction with a suitable peak location algorithm.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0010.003
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.233
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicAdvanced Fiber Optic SensorsFrench-language works237,207