MétaCan
Menu
Back to cohort
Record W1980413207 · doi:10.1503/cjs.000711

Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure

2012· article· en· W1980413207 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueCanadian Journal of Surgery · 2012
Typearticle
Languageen
FieldMedicine
TopicThyroid and Parathyroid Surgery
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineDiathermyHarmonic scalpelSurgeryLaparotomyHemostasisBlood loss

Abstract

fetched live from OpenAlex

BACKGROUND: New hemostatic technologies are often employed in open and laparoscopic surgery to reduce duration of surgery and complications. Monopolar diathermy, Harmonic scalpel and LigaSure are routinely used in open and laparoscopic surgery for tissue cutting and hemostasis. We compared lateral thermal damage following in vivo application of 3 commonly used instruments. METHODS: We used monopolar diathermy, Harmonic scalpel and LigaSure to coagulate and divide the peritoneum of patients who underwent median laparotomy. After anesthesia, median supraumbilical laparotomy was performed, and the peritoneum of each patient was coagulated using different devices. Using light microscopy and morphometric imaging analysis, the width of tissue lateral thermal damage was measured from the point of the peritoneal incision. RESULTS: We included 100 patients in our study. After a peritoneal incision, the mean lateral thermal damage of monopolar diathermy, Harmonic scalpel (output power 3), Harmonic scalpel (output power 5) and LigaSure were 215.79 μm, 90.42 μm, 127.48 μm and 144.18 μm, respectively. CONCLUSION: The degree of lateral thermal spread varied by instrument type, power setting and application time. LigaSure and Harmonic scalpel were the safest and most efficient methods of tissue coagulation. Monopolar diathermy resulted in the greatest degree of thermal damage in tissues.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.118
Threshold uncertainty score0.426

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.086
GPT teacher head0.314
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it