MétaCan
Menu
Back to cohort
Record W1982156835 · doi:10.1118/1.2761193

MO‐A‐BRB‐01: Review of the AAPM TG‐105

2007· article· en· W1982156835 on OpenAlexaff
I Chetty, DWO Rogers

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsCarleton University
Fundersnot available
KeywordsRadiation treatment planningVariance reductionComputer scienceMedical physicsProcess (computing)DosimetryMonte Carlo methodRadiation therapyNuclear medicinePhysicsMedicineMathematicsStatistics

Abstract

fetched live from OpenAlex

Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. Several commercial vendors have released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. Educational Objectives: 1. To provide an educational review of the physics of the MC including discussion of methods used for coupled photon and electron transport. 2. To review the methods used to improve the simulation efficiency. 3. To briefly review the vendor transport codes currently used for clinical treatment planning. 4. To describe the development of treatment head models for clinical treatment planning. 5. To discuss the factors associated with MC dose calculation within the patient‐specific geometry, such as statistical uncertainties, CT‐to‐material, and reporting of dose‐to‐medium versus dose‐to‐water. 6. To discuss the issues associated with experimental verification of MC algorithms. 7. To briefly review the potential clinical implications of MC calculated dose distributions. 8. To provide example timing comparisons of the major vendor MC codes in the clinical setting.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.020
Threshold uncertainty score0.067

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0120.010
Science and technology studies0.0010.001
Scholarly communication0.0020.003
Open science0.0030.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0200.023

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.315
Teacher spread0.298 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207