MétaCan
Menu
Back to cohort
Record W1982492290 · doi:10.1063/1.1554731

Analysis of heat transfer from single wires close to walls

2003· article· en· W1982492290 on OpenAlexaff
Junmei Shi, D. Gerlach, M. Breuer, F. Durst, Carlos F. Lange

Bibliographic record

VenuePhysics of Fluids · 2003
Typearticle
Languageen
FieldEngineering
TopicFluid Dynamics and Turbulent Flows
Canadian institutionsUniversity of Alberta
FundersDeutscher Akademischer Austauschdienst
KeywordsHeat transferLaminar flowMechanicsHeat fluxPhysicsBoundary layerConvective heat transferFlow (mathematics)ConvectionFluid dynamicsThermodynamics

Abstract

fetched live from OpenAlex

Two-dimensional numerical investigations of the forced heat convection from a microcylinder in laminar cross-flow, both in free stream and in near-wall flow, were carried out aiming at a better understanding of the physics behind the wall effects on hot-wire near-wall measurements. In the physical model, an infinitely thin plate with the same properties as the fluid (air) was used as an artificial wall. The conjugate heat transfer between the flow regions on both sides of the plate was taken into account. The effect of the conjugate thermal conditions (temperature distribution and diffusive heat flux) at the interface of the two flow regions on the heat transfer from the wire was investigated by varying the flow conditions on the side opposite to the wire location. Careful energy balance analysis was performed for both the free-stream case and the near-wall case. This enabled the authors to verify their own understanding of the physical mechanism responsible for the wall effect on hot-wire measurements and to examine other mechanisms proposed in the literature. The numerical results showed that the heat diffusion from the wire is significantly enhanced in the case of small wire-to-wall distances (Y+<3). This is mainly caused by modifications of the thermal boundary condition (diffusive effect) at the fluid–wall interface. In contrast, the flow distortion (enhanced convection) was shown not to be the most important influencing factor for the heat transfer of a hot wire. Although the present model study was performed for a laminar flow, the results obtained are applicable to hot-wire measurements in turbulent flows, as stated in the literature.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.255
Threshold uncertainty score0.550

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.205
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2003
Admission routes1
Has abstractyes

Explore more

Same venuePhysics of FluidsSame topicFluid Dynamics and Turbulent FlowsFrench-language works237,207