Temperature and Thermal Balance Monitoring and Control in Dialysis
Bibliographic record
Abstract
Temperature and thermal balance have been studied in an effort to explain better tolerance of ultrafiltration during isolated ultrafiltration and other convective techniques as compared to conventional hemodialysis. The large number of published studies has led to the conclusion that negative thermal balance of the extracorporeal circuit ameliorates hemodynamic stability by increased vasoreactivity and increased peripheral resistance. On the other hand, measurement of dialysis efficiency (urea removal) did not unequivocally confirm the theoretically predicted decrease in efficiency of "cool" dialysis. Another suggested application of temperature and thermal balance for assessing bioincompatibility is currently hampered by the ability of existing technology to evaluate thermal parameters of the extracorporeal circuit only. Publications on impact of negative thermal balance of the extracorporeal circuit on ultrafiltration-induced changes in blood volume give contradictory results. Further studies are needed for elucidation of the impact of thermal balance on overall biological response to dialysis.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".