MétaCan
Menu
← Back to cohort
Record W1983277393 · doi:10.1118/1.3612265

SU‐E‐T‐314: Challenges in Radiochromic Film Dosimetry Applied to Microbeam Radiation Therapy (MRT)

2011· article· en· W1983277393 on OpenAlexaffabout
Danielle Anderson, Brad Warkentin, Albert Siegbahn, B. G. Fallone

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsMicrobeamCollimatorDosimetryMaterials scienceMicrometerOpticsBeam (structure)Nuclear medicineRadiationScannerPhysicsMedicine

Abstract

fetched live from OpenAlex

Purpose: Uncertainties in radiochromic film dosimetry applied to microbeam radiation therapy (MRT) dosimetry at the Canadian Light Source (CLS) are investigated. A dose‐dependent change in film response as a function of microbeam width is characterized and its impact on peak‐to‐valley dose ratios (PVDRs) evaluated. Variation across the MRT collimator and inhomogeneity in film construction are also studied. Methods: Gafchromic® EBT2 film was used to measure doses from a filtered synchrotron source on the surface of solid water for microbeams ranging from 10 micrometers to 1 mm and doses between 0.4 – 74 Gy. The microbeams were generated using a variable slit or a MRT collimator (50 micrometer slits, 400 micrometer spacing). The film was scanned with an Epson Perfection V700 Photo digital scanner (4800 dpi). Corresponding Monte Carlo (PENELOPE) simulations were performed.Results: A dose‐dependent reduction in film response with decreasing microbeam width was observed. The measured ratio of dose for a 50 micrometer slit beam relative to a 1 mm beam ranged from 0.15 and 0.56, decreasing as the dose is increased. A corresponding simulation predicts a ratio of 0.91. Depending on dose, measured PVDRs ranged from 7 to 64. Variability in measured doses between different slits of the MRT collimator is also problematic, with deviations from the average of up to 26% in the microbeam path, and over 70% between two microbeams. Inherent inhomogeneity in optical density of the unexposed EBT2 film may also result in uncertainties of approximately 0.15 Gy. Conclusions: Although the high resolution of radiochromic film makes it a potentially attractive two‐dimensional dosimeter for MRT, large uncertainties arise from variations in dose‐response as a function of microbeam size, and spatial inhomogeneity of the response. These problems must be addressed before film can be considered for accurate measurement of absolute doses, and even relative metrics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.053

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.010
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.273
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→