MétaCan
Menu
Back to cohort
Record W1984631885 · doi:10.1002/jmri.21128

Improved dynamic susceptibility contrast (DSC)‐MR perfusion estimates by motion correction

2007· article· en· W1984631885 on OpenAlexaff
Robert K. Kosior, Jayme C. Kosior, Richard Frayne

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2007
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsHotchkiss Brain InstituteFoothills Medical CentreUniversity of Calgary
Fundersnot available
KeywordsImaging phantomPerfusionCerebral blood flowNuclear medicineMotion (physics)Contrast (vision)MedicineComputer sciencePerfusion scanningArtificial intelligenceComputer visionBiomedical engineeringRadiologyCardiology

Abstract

fetched live from OpenAlex

PURPOSE: To investigate the effect of patient motion on quantitative cerebral blood flow (CBF) maps in ischemic stroke patients and to evaluate the efficacy of a motion-correction scheme. MATERIALS AND METHODS: Perfusion data from 25 ischemic stroke patients were selected for analysis. Two motion profiles were applied to a digital anthropomorphic brain phantom to estimate accuracy. CBF images were generated for motion-corrupted and motion-corrected data. To correct for motion, rigid-body registration was performed. The realignment parameters and mean CBF in regions of interest were recorded. RESULTS: All patient data with motion exhibited visibly reduced intervolume misalignment after motion correction. Improved flow delineation between different tissues and a more clearly defined ischemic lesion (IL) were achieved in the motion-corrected CBF. A significant difference occurred in the IL (P < 0.05) for patients with severe motion with an average difference between corrupted and corrected data of 4.8 mL/minute/100 g. The phantom data supported the patient results with better CBF accuracy after motion correction and high registration accuracy (<1 mm translational and <1 degrees rotational error). CONCLUSION: Motion degrades flow differentiation between adjacent tissues in CBF maps and can cause ischemic severity to be underestimated. A registration motion correction scheme improves dynamic susceptibility contrast (DSC)-MR perfusion estimates.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.632
Threshold uncertainty score0.503

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.291
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207