MétaCan
Menu
Back to cohort
Record W1985147369 · doi:10.1134/s1054660x0812030x

Degree of conversion and temperature increase of a composite resin light cured with an argon laser and blue LED

2008· article· en· W1985147369 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueLaser Physics · 2008
Typearticle
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsnot available
FundersFundação de Amparo à Pesquisa do Estado de São Paulo
KeywordsMaterials scienceAbsorbanceComposite numberFourier transform infrared spectroscopyArgonLaserAnalytical Chemistry (journal)DiodeCuring (chemistry)Scanning electron microscopeSpectrometerOpticsComposite materialOptoelectronicsChemistry

Abstract

fetched live from OpenAlex

Different light sources and power densities used on the photoactivation process may provide changes in the degree of conversion (DC%) and temperature ( T ) of the composite resins. Thus, the purpose of this study was to evaluate the DC (%) and T (°C) of the microhybrid composite resin (Filtek™ Z-250, 3M/ESPE) photoactivated with one argon laser and one LED (light-emitting diode) with different power densities. For the KBr pellet technique, the composite resin was placed into a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated as follows: a continuous argon laser (CW) and LED LCUs with power density values of 100, 400, 700, and 1000 mW/cm 2 for 20 s. The measurements for DC (%) were made in a FTIR spectrometer Bomen (model MB 102, Quebec, Canada). Spectroscopy (FTIR) spectra for both uncured and cured samples were analyzed using an accessory of the reflectance diffusion. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm −1 resolution, 300 to 4000-cm −1 wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1638 cm −1 ) against an internal standard before and after the curing of the specimen: aromatic C-C (peak at 1608 cm −1 ). For T (°C), the samples were created in a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated for 20 s. The thermocouple was attached to the multimeter allowing temperature readings. The DC (%) and T (°C) were submitted to ANOVA and Tukey’s test ( p < 0.05). The degree of conversion values varied from 35.0 to 50.0% (100 to 1000 mW/cm 2 ) for an argon laser and from 41.0 to 49% (100 to 1000 mW/cm 2 ) for an LED. The temperature change values varied from 1.1 to 13.1 °C (100 to 1000 mW/cm 2 ) for an argon laser and from 1.9 to 15.0 °C (100 to 1000 mW/cm 2 ) for an LED. The power densities showed a significant effect on the degree of conversion and changes the temperature for both lightcuring units.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.092
Threshold uncertainty score0.313

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.223
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it