MétaCan
Menu
Back to cohort
Record W1985853895 · doi:10.1016/s0029-7844(01)01386-2

Transvaginal ultrasound and digital examination in predicting successful labor induction

2001· article· en· W1985853895 on OpenAlex
Sujata Chandra

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueObstetrics and Gynecology · 2001
Typearticle
Languageen
FieldMedicine
TopicMaternal and Perinatal Health Interventions
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMedicineConfidence intervalOdds ratioLabor inductionBishop scorePregnancyGestationUltrasoundVaginal deliveryObstetricsLogistic regressionGynecologyVaginaSurgeryCervixRadiologyInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: To compare transvaginal ultrasound and digital cervical examination in predicting successful induction in post-term pregnancy. METHODS: Transvaginal ultrasound and digital vaginal examinations were performed on 122 women at 41 or more weeks' gestation, immediately before labor induction. Ultrasound assessments of cervical length, dilatation, and presence of funneling were compared with the components of the Bishop score. The primary outcome was the rate of vaginal delivery. Secondary outcomes assessed included the rates of active labor in 12 hours, vaginal delivery in 12 and 24 hours, mean duration of latent phase, and induction to vaginal delivery interval. Linear and multiple logistic regression models were generated to identify factors independently associated with successful induction. RESULTS: No ultrasound characteristic predicted primary or secondary outcomes. Bishop score (odds ratio [OR] 2.98, 95% confidence interval [CI] 1.71, 5.20), cervical position (OR 4.35, 95% CI 1.41, 12.50), and maternal age (OR 1.15, 95% CI 1.01, 1.30) independently predicted vaginal delivery. Maternal weight (OR 0.96, 95% CI 0.94, 0.98), cervical dilatation (OR 6.08, 95% CI 1.70, 21.68), and effacement (OR 2.34, 95% CI 1.16, 4.73) independently predicted active labor in 12 hours. Independent predictors of vaginal delivery in 12 hours were induction method (P <.001), cervical dilatation (OR 11.16, 95% CI 3.17, 39.29), gravidity (OR 2.06, 95% CI 1.13, 3.77), and maternal weight (OR 0.96, 95% CI 0.93, 0.99). Cervical effacement (OR 2.70, 95% CI 1.59, 4.57) and parity (OR 7.10, 95% CI 2.22, 22.72) independently predicted vaginal delivery in 24 hours. Maternal weight, cervical position, and cervical dilatation were independently associated with latent phase labor duration. Factors independently associated with length of induction to delivery interval were parity, cervical effacement, and maternal weight. CONCLUSION: Transvaginal ultrasound does not predict successful labor induction in post-term pregnancy as well as digital cervical examination.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.163
Threshold uncertainty score0.231

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.290
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it