MétaCan
Menu
Back to cohort
Record W1986163623 · doi:10.1163/156855309x431668

Design and Control of a Hydraulic Simulator for a Flexible-Joint Robot

2009· article· en· W1986163623 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueAdvanced Robotics · 2009
Typearticle
Languageen
FieldEngineering
TopicHydraulic and Pneumatic Systems
Canadian institutionsUniversity of Saskatchewan
Fundersnot available
KeywordsAccelerationControl theory (sociology)RobotEngineeringSimulationFlexibility (engineering)Hydraulic machineryControl engineeringActuatorComputer scienceMechanical engineeringArtificial intelligenceControl (management)

Abstract

fetched live from OpenAlex

For the first time, a novel experimental hydraulic system that simulates joint flexibility of a single-rigid-link flexible-joint robot manipulator, with the ability of changing the joint flexibility's parameters, was designed and implemented in this study. Such a system could facilitate future control studies of robot manipulators by reducing investigation time and implementation cost of research. It could also be used to test the performance of different strategies to control the movement of flexible-joint manipulators. A hydraulic rotary servo motor was used to simulate the action of a flexible-joint robot manipulator, which was a challenging task, since the control of angular acceleration was required. In this study, a single-rigid-link elastic-joint robot manipulator was mathematically modeled and implemented in which joint flexibility parameters such as stiffness and damping could be easily changed. This simulation is referred to as a 'function generator' to drive a hydraulic robot manipulator. In this study the desired angular acceleration of the manipulator was used as the input to the hydraulic rotary motor and the objective was to make the hydraulic system follow the desired acceleration in the frequency range specified. A hydraulic actuator robot was built and tested. The results indicated that if the input signal had a frequency in the range of 5–15 Hz and damping ratio of 0.1 (typical values for flexible joints), the experimental setup was able to reproduce the input signal with acceptable accuracy. Owing to the inherent noise associated with the measurement of acceleration and some severe nonlinearities in the rotary motor, control of the experimental test system using classical methods was a challenging task that had not been anticipated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.904
Threshold uncertainty score0.615

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.237
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it