<title>Tritium-activated RGB reference sources for the calibration of CRTs</title>
Bibliographic record
Abstract
This paper proposes the use of tritium-activated light sources made up of CRT phosphors to act as transfer devices between reference spectro radiometers and CRT color measuring instruments. We describe the composition and characteristics of these sources and discuss their suitability as standards. We report on the laboratory measurement and testing of sources of similar nature obtained from a safety sign manufacturer. In these experiments we tried to tag red, green and blue sources with precise tristimulus values in order that they could serve as reference targets for the application of matrix correction methods to colorimeters. We find that chromaticity values can indeed be obtained with adequate accuracy. The establishment of reference luminance values was found to be problematic because the set of sources used showed noticeable spatial non-uniformity, a problem that should be overcome by tighter control of the fabrication process and careful sample selection.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.006 | 0.003 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".