MétaCan
Menu
Back to cohort
Record W1987788334 · doi:10.5414/cpp44284

Bioequivalence of abacavir generic and innovator formulations under fasting and fed conditions

2006· article· en· W1987788334 on OpenAlexaff
Jean‐Francois Marier, Miguel Borges, G. Plante, Marika DiMarco, G. Morelli, Sudhakar Koundinya Tippabhotla, T Vijan, Anand Singla, M Garg, Tausif Monif

Bibliographic record

VenueInternational Journal of Clinical Pharmacology and Therapeutics · 2006
Typearticle
Languageen
FieldMedicine
TopicHIV/AIDS drug development and treatment
Canadian institutionsBioPhage Pharma (Canada)
Fundersnot available
KeywordsAbacavirBioequivalenceCmaxInnovatorPharmacokineticsPharmacologyBioavailabilityArea under the curveChemistryChromatographyMathematicsMedicineHuman immunodeficiency virus (HIV)Viral load

Abstract

fetched live from OpenAlex

OBJECTIVE: Abacavir sulfate is a synthetic carbocyclic nucleoside analogue indicated for the treatment of HIV-1 infection in combination with other antiretroviral agents. The objective of the current study was to determine the bioequivalence between a generic formulation of abacavir and the innovator product. MATERIAL AND METHODS: A total of 80 subjects were randomly assigned to receive a single 300 mg oral dose of abacavir sulfate as the generic (Ranbaxy-Abacavir, Ranbaxy Laboratories Ltd., equivalent to 300 mg of abacavir) and innovator (Ziagen, GlaxoSmithKline) tablet formulations in 2-way crossover studies performed under fasting (n=40) and fed (n=40) conditions. Multiple blood samples were collected over 14 hours and plasma concentrations of abacavir were assayed using an LC/MS/MS method with a limit of quantitation of 25.0 ng/ml. Pharmacokinetic (PK) parameters were calculated using noncompartmental methods. RESULTS: Under fasting conditions, geometric mean area under the curve from time 0 to the last measurable concentration (AUC(0-t)), area under the curve extrapolated to infinity (AUC(0-infinity) and maximum plasma concentrations (Cmax) of abacavir for the generic (5565 ng x h/ml, 5668 ng x h/ml and 2526 ng/ml, respectively) and innovator (5675 ng x h/ml, 5770 ng x h/ml and 2528 ng/ml, respectively) products were very similar. Under fed conditions, mean values of AUC(0-t) AUC(0-infinity) and Cmax for the generic (4487 ng x h/ml, 4571 ng x h/ml and 1841 ng/ml, respectively) and innovator (4574 ng x h/ml, 4654 ng x h/ml and 1781 ng/ml, respectively) formulations were also very similar. Ratios of LSM and 90% confidence intervals of PK parameters between the 2 formulations were within 80.0 - 125.0% under fasting and fed conditions, suggesting that the 2 tablet formulations resulted in similar rate and extent of bioavailability. Adverse events for the generic and innovator products were similar in nature and frequency in the fasting and fed studies. CONCLUSIONS Based on the above results, the generic tablet formulation of abacavir developed by Ranbaxy should be equally effective as the innovator product.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.226

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.087
GPT teacher head0.454
Teacher spread0.367 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Clinical Pharmacology and TherapeuticsSame topicHIV/AIDS drug development and treatmentFrench-language works237,207