MétaCan
Menu
Back to cohort
Record W1989027364 · doi:10.1118/1.4737095

External respiratory motion: Shape analysis and custom realistic respiratory trace generation

2012· article· en· W1989027364 on OpenAlexaff
Sarah Quirk, Nathan Becker, Wendy Smith

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsPrincess Margaret Cancer CentreFoothills Medical CentreUniversity of Calgary
Fundersnot available
KeywordsAkaike information criterionTRACE (psycholinguistics)PopulationImaging phantomMotion (physics)Sigmoid functionRespiratory systemComputer scienceMedicineAmplitudeSoftwareStatisticsSimulationNuclear medicineMathematicsArtificial intelligencePhysicsInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: The authors developed a realistic respiratory trace generating (RTG) tool for use with phantom and simulation studies. METHODS: The authors analyzed the extent of abdominal wall motion from a real-time position management system database comprised of 125 lung, liver, and abdominal patients to determine the shape and extent of motion. Using Akaike's information criterion (AIC), the authors compared different model types to find the optimal realistic model of respiratory motion. RESULTS: The authors compared a family of sigmoid curves and determined a four parameter sigmoid fit was optimal for over 98% patient inhale and exhale traces. This fit was also better than sin (2)(x) for 98% of patient exhale and 70% of patient inhale traces and better than sin (x) for 100% of both patient inhale and exhale traces. This analysis also shows that sin (2)(x) is better than sin (x) for over 95% of patient inhale and exhale traces. With results from shape and extent of motion analysis, we developed a realistic respiratory trace generating (RTG) software tool. The software can be run in two modes: population and user defined. In population mode, the RTG draws entirely from the population data including inter- and intra fraction amplitude and period variability and baseline drift. In user-defined mode, the user customizes the respiratory parameters by inputting the peak-to-peak amplitude, period, end exhale position, as well as controls variability in these parameters and baseline drift. CONCLUSIONS: This work provides a method of generating custom respiratory data that can be used for initial implementation and testing of new technologies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.586
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.311
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207