MétaCan
Menu
Back to cohort
Record W1989281836 · doi:10.1213/ane.0b013e31816d15c9

A Comparison of GlideScope® Videolaryngoscopy to Direct Laryngoscopy for Nasotracheal Intubation

2008· article· en· W1989281836 on OpenAlexaff
Philip M. Jones, Kevin Armstrong, Paidrig Armstrong, Richard A. Cherry, Christopher Harle, Jason Hoogstra, Timothy P. Turkstra

Bibliographic record

VenueAnesthesia & Analgesia · 2008
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineLaryngoscopyNasotracheal intubationLaryngoscopesIntubationAnesthesiaVideo laryngoscopeTracheal intubation

Abstract

fetched live from OpenAlex

In Brief BACKGROUND: In this study, we compared the effectiveness of direct laryngoscopy (DL) and the GlideScope® videolaryngoscope (GVL) for nasotracheal intubation, as judged by the time to intubation (TTI—the primary outcome) and the ease of intubation. METHODS: Seventy patients requiring nasotracheal intubation for elective surgery were randomly allocated to intubation with the GVL or DL. TTI was assessed by a blinded observer. Operators were blinded until the start of laryngoscopy. A Visual Analog Scale assessed the ease of intubation. The number of intubation attempts, number of failures, glottic grades, amount of bleeding, usage of Magill forceps, and the severity of postoperative sore throat were recorded. RESULTS: The median TTI was 23.2 s faster with the GVL (43.5 s, interquartile range [IQR]: 39.8–67.3) than with DL (66.7 s, IQR: 53.8–89.9), P = 0.0023. Nasotracheal intubation was easier with the GVL than with DL (Visual Analog Scale 10 mm, IQR: 5.5–18, vs 20 mm, IQR: 10–32, P = 0.0041). The incidence of postoperative moderate or severe sore throat was significantly reduced in the GVL group (9% vs 34%, P = 0.018). Glottic exposure was significantly better with the GVL. Magill forceps were not used in the GVL group, but were used 49% of the time in the DL group, P < 0.0001. The incidence and severity of bleeding were similar between groups. CONCLUSIONS: Compared with DL, the GVL has superior performance characteristics when used for nasotracheal intubation and demonstrates an important reduction of postoperative sore throat. The GVL has a clear role in routine nasotracheal intubation. IMPLICATIONS: A prospective, randomized, blinded, clinical trial was conducted to assess the effectiveness of the GlideScope for nasotracheal intubation. When compared with direct laryngoscopy, GlideScope videolaryngoscopy was faster, easier, and resulted in a much lower incidence of sore throat postoperatively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.362
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations103
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueAnesthesia & AnalgesiaSame topicAirway Management and Intubation TechniquesFrench-language works237,207