MétaCan
Menu
← Back to cohort
Record W1990039428 · doi:10.1118/1.4813931

SU‐C‐105‐07: A New Criterion for Detector Usability in Nonstandard Beam Dosimetry

2013· article· en· W1990039428 on OpenAlexaff
Yuji Kamio, Hugo Bouchard

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsHôpital Notre-DameUniversité de Montréal
Fundersnot available
KeywordsDetectorPhysicsDosimetryIonization chamberMonte Carlo methodBeam (structure)OpticsLimit (mathematics)CentroidPhotonComputational physicsNuclear physicsIonizationMathematicsStatisticsNuclear medicineMathematical analysisGeometryQuantum mechanics

Abstract

fetched live from OpenAlex

Purpose: To accurately convert the detector signal to absorbed dose to water in nonstandard beams, beam quality correction factors (kQ) are required. To avoid calculating such factors, we define a criterion based on the hypothesis that, for a given detector, kQ is unity within a given tolerance. This allows establishing detector‐specific critical regions to limit the field sizes usable experimentally without the need for evaluating kQ. Methods: A theoretical relation between the relative deviation of kQ from unity and a function that depends on dose response kernels is derived. Kernels are computed using the Monte Carlo user code egs_chamber for water and for three different ionization chambers (Exradin A12, A14 and A1SL), simulating 6 MV photon pencil beams at several lateral positions. Critical regions around the centroid of the chambers that guarantee kQ to remain within +/−0.005 from unity are obtained. For field sizes equal to the critical regions, kQ factors are calculated to validate the theoretical approach. Results: To limit kQ within +/−0.005 from unity, field sizes were determined to be 2.6× 5.2 cm2 for the A12, 3.8 × 3.8 cm2 for the A14 and 2.5 × 2.9 cm2 for the A1SL chamber. The corresponding kQ were found to be 1.0019 +/− 0.0026 for the A12, 1.0001 +/− 0.0047 for the A14 and 1.0011 +/− 0.0024 for the A1SL. These results are found within the expected deviation and fully support the validity of the new criterion. Conclusion: In this study, the limitation of the field size to a detector‐specific critical region allows small beam measurements to be done without the need for evaluating kQ factors. While this work will be extended to other types of detectors, the methodology will serve as a basis to study IMRT beams in the scope of new dosimetry protocols.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.027
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.009
Threshold uncertainty score0.047

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.027
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0020.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.300
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→