MétaCan
Menu
Back to cohort
Record W1990884423 · doi:10.1118/1.2761315

TU‐B‐M100J‐01: Optimizing Mammography Image Quality and Dose: X‐Ray Spectrum and Exposure Parameter Selection

2007· article· en· W1990884423 on OpenAlexaff
Michael Williams, Priya Raghunathan, JA Seibert, Alexander L. C. Kwan, Joseph Y. Lo, Ehsan Samei, Nicole T. Ranger, Laurie L. Fajardo, Allen McGruder, S. Maxwell, Andrew D. A. Maidment, Martin J. Yaffe, Aili K. Bloomquist, Gordon E. Mawdsley

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsImaging phantomAutomatic exposure controlMammographyDigital mammographyImage qualityNuclear medicineContrast-to-noise ratioDosimetryFilter (signal processing)Computer scienceArtificial intelligenceMedicineComputer visionImage (mathematics)Breast cancer

Abstract

fetched live from OpenAlex

Optimization of exposure parameters (target, filter, and kVp) in digital mammography necessitates maximization of the image signal‐to‐noise ratio (SNR), while simultaneously minimizing patient dose. The goal of this talk is to compare, for each of the major commercially available full field mammography (FFDM) systems, the impact of the selection of technique factors on image SNR and radiation dose for a range of breast thickness and tissue types. The comparison will be based on the results of a multi‐center phantom study. The five commercial FFDM systems tested, the Senographe 2000D from GE Healthcare, the Mammomat Novation from Siemens, and the Selenia from Hologic, the Fischer Senoscan, and Fuji's 5000MA used with a Lorad M‐IV mammography unit, are located at five different university test sites. Performance was assessed using all available x‐ray target and filter combinations and nine different phantom types (three compressed thicknesses, and three tissue composition types). Each phantom type was also imaged using the automatic exposure control (AEC) of each system to identify the exposure parameters used under automated image acquisition. The figure of merit (FOM) used to compare technique factors is the ratio of the square of the image SNR to the mean glandular dose (MGD). The results show that, for a given target/filter combination, in general FOM is a slowly changing function of kVp, with stronger dependence on the choice of target/filter combination. In all cases the FOM was a decreasing function of kVp at the top of the available range of kVp settings, indicating that higher tube voltages would produce no further performance improvement. For a given phantom type, the exposure parameter set resulting in the highest FOM value was system‐specific, depending on both the set of available target/filter combinations, and on the receptor type. Noise performance differed noticeably among the FFDM systems and played an important role in determining relative FOM values. In most cases, the AECs of the FFDM systems successfully identified exposure parameters resulting in FOM values near the maximum ones, however there were several examples where AEC performance could be improved. Educational Objectives: 1. become familiar with the effect of changing kVp, target material, and filtration on the mean glandular dose for a variety of breast. 2. become familiar with the effect of changing kVp, target material, and filtration on image signal and noise for specific commercial FFDM systems. 3. learn how the exposure technique factors selected for a variety of breast types by the AECs of current FFDM systems compare with the technique factors resulting in optimal FOM values.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.743
Threshold uncertainty score0.718

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.291
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207