MétaCan
Menu
Back to cohort
Record W1991567111 · doi:10.1049/el:20058232

Threshold voltage shift compensated active pixel sensor array for digital X-ray imaging in a-Si technology

2005· article· en· W1991567111 on OpenAlexaff
N. Safavian, Jhih‐Siang Lai, John Rowlands, Arokia Nathan

Bibliographic record

VenueElectronics Letters · 2005
Typearticle
Languageen
FieldEngineering
TopicThin-Film Transistor Technologies
Canadian institutionsSunnybrook Health Science CentreUniversity of TorontoUniversity of Waterloo
Fundersnot available
KeywordsThin-film transistorThreshold voltageMaterials scienceOptoelectronicsPixelVoltageAmorphous siliconTransistorSiliconImage sensorAmorphous solidActive matrixElectrical engineeringOpticsPhysicsEngineeringNanotechnologyCrystalline silicon

Abstract

fetched live from OpenAlex

A new active pixel sensor for X-ray digital imaging using amorphous silicon thin-film transistors (a-Si TFTs) is proposed. Simulation results show that this new APS structure is fully capable of compensating for variations in threshold voltage (VT) of a-Si TFTs under prolonged gate voltage stress.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.206
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.196
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueElectronics LettersSame topicThin-Film Transistor TechnologiesFrench-language works237,207