MétaCan
Menu
Back to cohort
Record W1991693155 · doi:10.1118/1.3469560

TH-D-201B-01: Task-Based Analysis of Detectability in Tomosynthesis and Cone-Beam CT: Validation of Fourier Metrics in Comparison to Real Observers

2010· article· en· W1991693155 on OpenAlexaff
Grace J. Gang, Junghoon Lee, J. Webster Stayman, Daniel J. Tward, Wojciech Zbijewski, Jerry L. Prince, J. H. Siewerdsen

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsImaging phantomObserver (physics)Image qualityTomosynthesisCone beam computed tomographyComputer scienceNoise (video)Artificial intelligenceMedical imagingComputer visionMathematicsOpticsMammographyPhysicsImage (mathematics)Computed tomography

Abstract

fetched live from OpenAlex

Purpose: Image quality modeling is important in the development and optimization of imaging systems. In this work, detectability index (d') was derived from a task-based 3D cascaded systems model for tomosynthesis and cone-beam CT (CBCT). The extent to which detectability index presents a meaningful performance metric was assessed by direct comparison with human observer response over a broad range of imaging conditions and tasks. Methods: Detectability index was generalized to include anatomical background as an additional power-law noise source. Four observer models were investigated: pre-whitening, nonprewhitening, and variations thereof with eye filter and internal noise. A phantom was designed to present power-law noise, providing an experimental basis for observer studies. Imaging tasks included a range of detection and discrimination tasks in both uniform and power-law backgrounds. Human observer performance was measured from 9AFC tests, and directly compared with theoretical d' in terms of area under the ROC curve, Az, as a function of imaging task and orbital extent (qtot). Results: Theoretical d' demonstrated reasonable correspondence with real observers for all tasks and orbital extents. Typical cases showed increasing Az with qtot due to rejection of out-of-plane clutter, while constant-dose cases showed that Az could decline with qtot due to increased quantum noise and view aliasing. Prewhitening models tended to overestimate observer performance, whereas non-prewhitening models yielded fair agreement. While not specific to any particular application, the results quantitatively identify system design and technique considerations for applications in breast and chest tomosynthesis and CBCT. Conclusions: Generalized detectability index was validated with real observer performance across a wide range of imaging conditions and tasks, thereby providing a meaningful metric based on prevalent Fourier-based characterization of imaging performance. The results identify a framework for optimizing tomosynthesis and CBCT performance and begin to bridge the gap between Fourier- and observer-based image quality characterization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.312
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Dose and ImagingFrench-language works237,207