MétaCan
Menu
Back to cohort

Contact Lens-Induced Corneal Swelling and Surface Changes Measured with the Orbscan II Corneal Topographer

2004· article· en· W1991754374 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueOptometry and Vision Science · 2004
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSwellingContact lensCorneaLens (geology)OphthalmologyMaterials sciencePolymethyl methacrylateEffects of long-term contact lens wear on the corneaMedicineOpticsComposite material

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to measure central and topographical corneal swelling in response to contact lens wear and eye closure, to determine whether the swelling induced by soft and polymethyl methacrylate (PMMA) lenses is different, and to determine whether the anterior and/or posterior corneal shape alters with corneal swelling. METHODS: An Orbscan II corneal topographer was used to measure corneal swelling and the shape of the anterior and posterior corneal surfaces of 16 neophytes before and after wearing soft and PMMA contact lenses with near-zero oxygen transmissibility. The lens-wearing eye was patched for 3 h. RESULTS: The mean 15.1% +/- 3.8% (+/- SD) central corneal swelling with soft lenses was significantly >12.6% +/- 4.1% with PMMA lenses. Topographical corneal swelling was significantly greater with soft vs. PMMA lenses. However, the difference between central and peripheral corneal swelling was much greater with PMMA lenses. With both lenses, the cornea swelled significantly more in the center than the periphery. The anterior best-fit sphere radius remained unchanged in response to soft lenses (0.00 +/- 0.04 mm) and steepened slightly but significantly with PMMA lenses (-0.04 +/- 0.05 mm). The posterior best-fit sphere radius flattened significantly with both lenses (0.12 +/- 0.07 mm with soft and 0.14 +/- 0.08 mm with PMMA lenses). CONCLUSIONS: Corneal swelling (greater centrally than peripherally) flattens the posterior surface of the cornea and is independent of lens type. Although the anterior best-fit sphere radius steepened with PMMA, the magnitude is probably clinically unimportant. Both lens types produced greater central vs. peripheral corneal swelling. However, the soft lens induced significantly greater overall swelling than PMMA. Because their oxygen transmission was the same, these results suggest that there is lateral diffusion of oxygen from the peripheral area of the cornea (that is not covered by the lens) toward the center.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.546
Threshold uncertainty score0.580

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.347
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it