New devices to deliver somatosensory stimuli during functional MRI
Bibliographic record
Abstract
A new class of devices are described for improving investigation of somatosensory neuronal activation using fMRI. Dubbed magnetomechanical vibrotactile devices (MVDs), the principle of operation involves driving wire coils with small oscillatory currents in the large static magnetic field inherent to MRI scanners. The resulting Lorentz forces can be oriented to generate large vibrations that are easily converted to translational motions as large as several centimeters. Representative data demonstrate the flexibility of MVDs to generate different well-controlled vibratory and tactile stimuli to activate special proprioceptive and cutaneous somatosensory afferent pathways. The implications of these data are discussed with respect to the literature on existing devices for producing sensorimotor activation, as well as expanding the scope of current fMRI investigations.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".