GreenLight™ Laser (XPS) Photoselective Vapo-Enucleation versus Holmium Laser Enucleation of the Prostate for the Treatment of Symptomatic Benign Prostatic Hyperplasia: A Randomized Controlled Study
Bibliographic record
Abstract
PURPOSE: After the advent of the GreenLight XPS™ (180 W) 532 nm laser, photoselective vapo-enucleation of the prostate could compete with holmium laser enucleation of the prostate as a size independent procedure. We assessed whether photoselective vapo-enucleation of the prostate-XPS is not less effective than holmium laser enucleation of prostate for improvement of lower urinary tract symptoms secondary to benign prostatic hyperplasia. MATERIALS AND METHODS: A randomized controlled noninferiority trial comparing holmium laser enucleation of the prostate to photoselective vapo-enucleation of the prostate-XPS 180 W was conducted. I-PSS, flow rate, residual urine, prostate specific antigen and prostate volume changes as well as perioperative and late adverse events were compared. Noninferiority of I-PSS at 1 year was evaluated using a 1-sided test at 5% level of significance. The statistical significance of other comparators was assessed at the (2-sided) 5% level. RESULTS: Overall 50 and 53 patients were included in the holmium laser enucleation and photoselective vapo-enucleation of the prostate groups, respectively. Operative time, hospital stay and time to catheter removal were comparable between the groups. There was significant, comparable improvement in I-PSS and post-void residual urine volume at 1, 4 and 12 months. After 4 months prostate size reduction was significantly higher in the holmium laser enucleation of prostate group (74.3% vs 43.1%, p=0.001). At 12 months maximum urine flow rate was significantly higher in the holmium laser enucleation of prostate group (26.4 ±11.5 vs 18.4 ±7.5 ml per second, p=0.03). Re-intervention was needed in 2 and 3 cases in the holmium laser enucleation and photoselective vapo-enucleation of the prostate groups, respectively (p=1.0). Mean estimated cost per holmium laser enucleation of prostate procedure was significantly lower than per photoselective vapo-enucleation of the prostate procedure. CONCLUSIONS: Compared to holmium laser enucleation of prostate, GreenLight XPS laser photoselective vapo-enucleation of the prostate is safe, noninferior and effective in treatment of benign prostatic hyperplasia.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.003 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.004 | 0.003 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.002 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.002 | 0.002 |
| Insufficient payload (model declined to judge) | 0.006 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".