MétaCan
Menu
Back to cohort
Record W1993971628 · doi:10.1063/1.4757312

In vivo localized harmonic motion imaging of VX2 tumors

2012· article· en· W1993971628 on OpenAlexafffund
Laura Curiel, Kullervo Hynynen

Bibliographic record

VenueAIP conference proceedings · 2012
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsSunnybrook Health Science CentreLakehead UniversityUniversity of TorontoThunder Bay Regional Research Institute
FundersNational Institutes of HealthTerry Fox Foundation
KeywordsTransducerAmplitudeMagnetic resonance imagingUltrasoundIn vivoMaterials scienceHarmonicPhysicsSecond-harmonic imaging microscopyBiomedical engineeringNuclear magnetic resonanceOpticsMedicineRadiologyAcousticsSecond-harmonic generationLaser

Abstract

fetched live from OpenAlex

We evaluated the feasibility of localized harmonic motion (LHM) imaging for tumor detection in vivo. LHM was induced using a single-element focused ultrasound (FUS) transducer (80 mm focal, 100 mm diameter, 1.54 MHz) and a separate transducer (5 kHz PRF, 5 MHz) was used to track motion by cross-correlating RF signals. A scan was performed with the transducers assembly and LHM was induced 5 times per location. Images were formed averaging the calculated LHM amplitudes. Ten New Zealand rabbits had VX2 tumors implanted on their thighs. Tumors were located using Magnetic resonance images and LHM images were obtained. Eight out of ten tumors were visualized on LHM images as a region with lower amplitude (5.7±1.3μm in tumors and 19.5±5.8μm in muscle). All tumors had an elongated shape running along the muscle fibers. It was possible to detect tumors larger than 4mm in width (short axis of the tumor). We performed a FUS ablation of one tumor and the ablated region was detected as well on LHM images as a reduced LHM amplitude region.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.228
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueAIP conference proceedingsSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207