MétaCan
Menu
← Back to cohort
Record W1994047027 · doi:10.1118/1.1997573

SU-FF-J-27: Novel 4D CT Scanning Protocol Using a Helical Single-Slice CT Scanner

2005· article· en· W1994047027 on OpenAlexaff
Gabriela Stroian, Emily Heath, D. Louis Collins, Jan Seuntjens

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMontreal General Hospital
Fundersnot available
KeywordsTorsoScannerImaging phantomNuclear medicineBreathingHelical scanMedical imagingBiomedical engineeringMedicineComputer scienceRadiologyArtificial intelligenceAnatomyComputer hardware

Abstract

fetched live from OpenAlex

Purpose: In radiotherapy, respiratory motion poses a significant challenge during tumors imaging, treatment planning and radiation delivery. A method to alleviate respiratory motion problems is to use 4D radiotherapy. We propose novel 4D CT scanning protocol using a helical single-slice CT scanner (SSCT). Method and Materials: In our protocol, patient's torso is scanned three times using the helical mode of a SSCT scanner. CT slices are acquired simultaneously with real-time tracking of a marker placed on patient's torso. At the end of the three scans, CT data is binned into different respiratory phases according to the externally recorded respiratory signal and the volume of interest is reconstructed for several respiratory phases. Results: The protocol was tested on an anthropomorphic phantom to which a realistic respiratory motion was induced by placing it on an inflatable mattress driven by an air pump controlled by a pulsing power supply. 4D CT images were compared with images obtained after a conventional scan of the static phantom and with the conventional scan of the “breathing” phantom. 4D CT images show a net improvement with respect to conventional CT images. The ANIMAL deformable registration algorithm was used to calculate a 3D vector mesh which maps volumes at any given phase to the exhale volume. This vector map and the external breathing signal are used to reconstruct the anatomy at any breathing phase. Conclusion: Our scanning protocol uses the helical scan mode so it is faster than the axial/cine scanning protocols. The gap between CT slices available for each breathing scan is alleviated by taking three successive scans but the use of low tube current keeps the dose to the patient to an acceptable level. Our protocol is easy to implement in any clinic where a single-slice CT scanner and a real-time motion tracking system are available.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Protocol · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.336
Teacher spread0.306 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreProtocol

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→