MétaCan
Menu
Back to cohort
Record W1995079442 · doi:10.1115/1.2979867

The Force Attenuation Provided by Hip Protectors Depends on Impact Velocity, Pelvic Size, and Soft Tissue Stiffness

2008· article· en· W1995079442 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Biomechanical Engineering · 2008
Typearticle
Languageen
FieldMedicine
TopicBone health and osteoporosis research
Canadian institutionsSimon Fraser University
FundersNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsMichael Smith Health Research BC
KeywordsAttenuationSoft tissueStiffnessMaterials scienceMechanicsBiomedical engineeringPhysicsMedicineComposite materialSurgeryOptics

Abstract

fetched live from OpenAlex

Wearable hip protectors represent a promising strategy for preventing hip fractures. However, there is lack of agreement on biomechanical testing standards and subsequent uncertainty about the ability of hip protectors to attenuate impact force during a fall. To address this issue, we designed a fall impact simulator that incorporated a "biofidelic" surrogate pelvis, which matched the surface geometry and soft tissue stiffness measured in elderly women (n=15). We then used this system to measure the attenuation in peak femoral neck force provided by two commercially available soft shell protectors (Safehip Soft and Hipsaver) and one rigid shell protector (Safehip Classic). Finally, we examined how the force attenuation provided by each protector was influenced by systematic changes in fall severity (impact velocity), body size (pelvis size), and soft tissue stiffness. With the biofidelic pelvis, the force attenuation averaged over all impact velocities was 27% for Safehip Soft, 17% for Safehip Classic, and 19% for Hipsaver. However, the rank order of hip protectors (and especially the performance of Safehip Classic) varied with the test conditions. Safehip Classic attenuated force by 33% during a low velocity (1 ms) fall, but only by 8% for a high velocity (4 ms) fall. In the latter condition, improved attenuation was provided by the soft shell hip protectors (19% by Safehip Soft and 21% by Hipsaver). As soft tissue stiffness increased from softest to most rigid, the attenuation provided by Safehip Classic increased 2.9-fold (from 26% to 76%), while Safehip Soft increased 1.7-fold (from 36% to 60%) and Hipsaver increased 1.1-fold (from 36% to 38%). As pelvis size decreased from largest to smallest, the attenuation provided by Safehip Classic increased 8-fold, but for a high velocity fall and moderate tissue stiffness, never exceeded that provided by Safehip Soft and Hipsaver. Our results indicate that, under biofidelic testing conditions, the soft shell hip protectors we examined generally provided greater force attenuation (averaging up to 27%) than the hard shell protector. Measured values of force attenuation were highly sensitive to variations in impact velocity, pelvic size, and pelvic soft tissue stiffness. This indicates the need to develop international testing standards to guide market approval, the selection of protectors for clinical trials, and the design of improved hip protectors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.256
Threshold uncertainty score0.349

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.304
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it