Systematic review: Misoprostol compared with prostaglandin E <sub>2</sub> for labour induction in women at term with intact membranes and unfavourable cervix: a systematic review*
Bibliographic record
Abstract
BACKGROUND: Misoprostol is a commonly used prostaglandin to induce labour. A potential risk of induction, however, is caesarean delivery, especially in women with an unfavourable cervix. OBJECTIVES: To evaluate the use of misoprostol, compared with prostaglandin E2 (PgE2), for labour induction in women at term with an unfavourable cervix and intact membranes. SEARCH STRATEGY: PubMed, Medline, EMBASE and the Cochrane Library were searched for articles published in any language from January 1987 to December 2005, using the keywords 'misoprostol', 'labour/labor' and 'induction'. SELECTION CRITERIA: We identified randomised trials of women at term (> or =37 weeks of gestation) with intact membranes and unfavourable cervix, undergoing labour induction with misoprostol, orally, vaginally, sublingually or buccally, compared with PgE2 vaginally or intracervically. DATA COLLECTION AND ANALYSIS: Caesarean delivery was the primary outcome, with tachysystole and hyperstimulation as secondary outcomes. The primary analysis compared any misoprostol with any PgE2 for all women, with a subgroup analysis for nulliparous women. Secondary analyses compared different routes and doses of misoprostol (oral or vaginal and 25 microgram or >25 microgram) and PgE2 (intracervical or vaginal). Relative risks (RR) and 95% confidence intervals (CI) were calculated using random effects models. Main results Fourteen of 611 articles identified met the criteria for systematic review, with three providing information for nulliparous women. There was no difference in the risk of caesarean delivery between misoprostol and PgE2 groups (RR = 0.99, 95% CI = 0.83-1.17). Any misoprostol was associated with higher risks of tachysystole and hyperstimulation compared with any PgE2 (RR = 1.86, 95% CI = 1.01-3.43 and RR = 3.71, 95% CI = 2.00-6.88, respectively). There was a higher rate of vaginal delivery within 24 hours among all vaginal deliveries with any misoprostol compared with any PgE2 (RR = 1.14, 95% CI = 1.00-1.31), and among all deliveries, a lower rate of oxytocin use (RR = 0.71, 95% CI = 0.60-0.85) but a trend towards increased meconium staining was observed (RR = 1.22, 95% CI = 0.96-1.55). The use of misoprostol at starting dosages >25 microgram had similar findings to the primary analysis. Studies of lower misoprostol dosing (starting dose of 25 microgram) did not show any differences in the outcomes of interest, but the sample size of this secondary analysis was small (304 women, 155 receiving misoprostol). AUTHOR'S CONCLUSIONS: Although misoprostol in women at term with an unfavourable cervix and intact membranes was more effective than PgE2 in achieving vaginal delivery within 24 hours, misoprostol does not reduce the rate of caesarean delivery either in all women or in the subgroup of nulliparous women, and it increases the rates of tachysystole and hyperstimulation. Further studies of misoprostol using a starting dose of 25 microgram may be warranted.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.005 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".