MétaCan
Menu
← Back to cohort
Record W1998038658 · doi:10.1118/1.3612325

SU‐E‐T‐371: Measurement of Transit Dose of An Ir‐192 HDR Brachytherapy Stepping Source Using a 2D‐Array of Ion Chambers

2011· article· en· W1998038658 on OpenAlexaff
Mammo Yewondwossen

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsDalhousie University
Fundersnot available
KeywordsIonization chamberDosimetryDosimeterBrachytherapyIonizationDose profileOpticsPhysicsBeam (structure)Nuclear medicineRadiationMaterials scienceRadiation therapyIonMedicine

Abstract

fetched live from OpenAlex

Purpose: The MatriXX Evolution 2D ionization chamber array is one of the 2D ionization chamber arrays developed by IBA dosimetry (IBA Dosimetry, Germany) for megavoltage real‐time absolute 2D dosimetry, verification of intensity‐modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). We have recently shown that this 2D ionization chamber array can be used for HDR brachytherapy Ir‐192 beam dose verification. The aim of this work is to investigate the use of the movie mode of the MatriXX Evolution for measurement of transit dose of the Ir‐192 source of a Nucletron Micro‐Selectron HDR brachytherapy unit. Methods: The MatriXX Evolution measurement can be performed in different measurement modes depending on the measurement situation. For megavoltage dynamic field measurement the 2D ionization chamber array is equipped with movie mode to perform measurements continuously. During this measurement each single shot is saved and can be viewed, played as a movie, or analyzed afterwards. The integration time for each sample or movie image can be varied by the user with the shortest sampling time being 20 ms. This dynamic mode measurement of the MatriXX Evolution was used to measure the entrance, exit and the inter‐dwell transit dose of the HDR source. Results: At a fixed point of measurement, the transit dose depends on the radioactive source strength and velocity along the trajectory. The transit dose measured with MatriXX Evolution move mode has been found to be consistent with that already presented by other dosimeters. Conclusions: The feasibility of using a 2D ionization chamber move mode in determining the transit dose of HDR stepping source is explored in the present work. Results of this investigation show that 2D ionization chamber move mode can be used to measure transit dose.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.286
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→