MétaCan
Menu
Back to cohort
Record W1998239498 · doi:10.2967/jnumed.111.088658

Reproducibility of Serial Left Ventricle Perfusion, Volume, and Ejection Fraction Measurements Using Multiplexed Multipinhole SPECT in Healthy Rats and Rats After Myocardial Infarction

2011· article· en· W1998239498 on OpenAlexafffund
Jared Strydhorst, Frans H. H. Leenen, Terrence D. Ruddy, R. Glenn Wells

Bibliographic record

VenueJournal of Nuclear Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsCarleton UniversityUniversity of Ottawa
FundersCanadian Institutes of Health ResearchUniversity of OttawaPfizer CanadaUniversity of Ottawa Heart Institute FoundationHeart and Stroke Foundation of CanadaPfizer
KeywordsReproducibilityMedicineVentricleNuclear medicinePerfusionEjection fractionMyocardial infarctionInfarctionCardiologyInternal medicineHeart failureChemistry

Abstract

fetched live from OpenAlex

UNLABELLED: Assessment of small-animal cardiac data acquired using SPECT requires an accurate understanding of the reproducibility and the uncertainties associated with the technique. Furthermore, it is also useful to have a baseline of reference data against which to compare the outcome of a particular study. METHODS: We scanned both healthy and post-myocardial infarction rats injected with (99m)Tc-tetrofosmin in a multidetector, multipinhole small-animal SPECT scanner. In this paper, we report on the creation of a reference database of the relative myocardial blood perfusion of rats. We also evaluated the reproducibility of perfusion measurements and measurements of left ventricle volume and ejection fraction, defined as the SD of a particular measurement repeated on the same animal or over multiple animals. RESULTS: For the healthy rats, interscan reproducibility of volume measurements was 4%-7% of the total volume, and intersubject reproducibility was 9%-12% of the volume being measured. Interscan reproducibility remained unaffected after infarction (6%-8%), but intersubject reproducibility was much poorer (15%-26%). Ejection fraction in healthy animals was highly reproducible between scans and between rats: 3.1% and 3.3%, respectively. Interscan reproducibility of the postinfarction ejection fraction was 3.6%; intersubject reproducibility after infarction was 8.1%. CONCLUSION: We have created a reference database for small-animal SPECT perfusion measurements in healthy male Sprague-Dawley rats and quantified the reproducibility of perfusion and functional measurement made with small-animal SPECT in healthy and postinfarction rats.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.159
Threshold uncertainty score0.424

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.299
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicCardiac Imaging and DiagnosticsFrench-language works237,207