MétaCan
Menu
Back to cohort
Record W1998359356 · doi:10.1161/strokeaha.111.635300

Residual Flow After Cerebral Aneurysm Coil Occlusion

2012· article· en· W1998359356 on OpenAlexaff
Pascale Lavoie, Jean‐Luc Gariépy, Geneviève Milot, Steve Jodoin, Fernand Bédard, François Trottier, René Verreault

Bibliographic record

VenueStroke · 2012
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsCentre hospitalier de l'Université Laval
Fundersnot available
KeywordsMedicineDigital subtraction angiographyAneurysmOcclusionRadiologyMagnetic resonance angiographyNuclear medicineAngiographyMagnetic resonance imagingSurgery

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: The purpose of this study was to estimate the performance measures of MR angiography (MRA) in the diagnosis of aneurysm residual flow after coil occlusion. METHODS: Patients having at least 1 cerebral aneurysm treated with coil occlusion were prospectively and consecutively enrolled. Time of flight and contrast-enhanced MRA were performed the same day of the DSA follow-up. The degree of aneurysm occlusion and dimensions of the residual flow were evaluated by independent readers at MRA and digital subtraction angiogram. MRA performance measures were estimated in a cross-sectional analysis and repeated in subgroups of aneurysm sizes and locations. MRA predictive values for recurrence were also estimated using a longitudinal design. RESULTS: We obtained 167 aneurysm evaluations for each imaging modality. Class 3 residual flow was seen on digital subtraction angiogram follow-up in 27%. The sensitivity and specificity of MRA was 88% (95% CI, 80-94) and 79% (95% CI, 67-88), respectively. The positive predictive value for a Class 3 recurrence was 67% (95% CI, 51-80) and the negative predictive value was 93% (95% CI, 86-97). Time-of-flight MRA underestimated the length of the residual flow (P=0.039), whereas contrast-enhanced MRA overestimated its width (P<0.0001). MRA sensitivity for a Class 3 residual flow was lower for aneurysms <6 mm (P=0.01). CONCLUSIONS: MRA has sufficient accuracy for screening of aneurysm residual flow after coil occlusion. Due to its lower negative predictive value, recurrent aneurysms should be confirmed with digital subtraction angiogram before planning a retreatment. Routine use of MRA to follow small aneurysms should wait better estimation of its performance in this particular subgroup.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.011
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.255
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueStrokeSame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207