MétaCan
Menu
Back to cohort
Record W1998436666 · doi:10.1117/12.713724

Intensity-modulated fluence patterns for task-specific imaging in cone-beam CT

2007· article· en· W1998436666 on OpenAlexaff
S. A. Graham, J. H. Siewerdsen, David A. Jaffray

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2007
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoOntario Institute for Cancer Research
Fundersnot available
KeywordsCone beam ctFluenceOpticsCone (formal languages)Intensity (physics)Beam (structure)Computer sciencePhysicsMaterials scienceComputed tomographyMedicineRadiologyAlgorithm

Abstract

fetched live from OpenAlex

Cone-beam CT images of a patient with a pre-defined distribution of noise in the image and dose to the patient can be accomplished through the development of advanced compensation schemes. Such compensation schemes involve delivery of x-ray fluence patterns that vary in intensity both across a single projection image (u,v) and for different projection view angles (θ) and provide the ability to perform intensity-modulated cone-beam CT. Implementation of an intensity-modulated cone-beam CT system for task-specific imaging has potential for tremendous reductions in patient dose and x-ray scatter reaching the detector. Pursuing this advanced imaging technique requires detailed characterization of the cone-beam CT platform. Determination of appropriately modulated fluence patterns relies on knowledge of numerous properties of the imaging system, including the constraints imposed by the modulator, the magnitude of x-ray scatter under different patient sizes and modulator positions, and properties of the detector. With an estimate of the patient anatomy and knowledge of the imaging system, an iterative process can be used to determine modulated fluence patterns corresponding to an image prescribed for the specific task and patient. Delivery of such modulated fluence patterns provide a CBCT image tailored to a specific patient and imaging task offering the optimum balance between image quality and patient dose. Specifically, arbitrary regions of interest requiring high image signal-to-noise ratio can be generated through knowledgeable spatio-angular intensity modulation, allowing image quality to degrade in other regions in order to minimize x-ray scatter and imaging dose.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.122
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.267
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207