MétaCan
Menu
Back to cohort
Record W1998830723 · doi:10.1118/1.3148668

A small-signal approach to temporal modulation transfer functions with exposure-rate dependence and its application to fluoroscopic detective quantum efficiency

2009· article· en· W1998830723 on OpenAlexaff
Saul N. Friedman, Ian A. Cunningham

Bibliographic record

VenueMedical Physics · 2009
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsLawson Health Research InstituteRobarts Clinical TrialsWestern University
Fundersnot available
KeywordsDetective quantum efficiencyOptical transfer functionAttenuationOpticsSIGNAL (programming language)Spatial frequencyFourier transformModulation (music)PhysicsMathematicsImage qualityComputer scienceAcousticsMathematical analysisArtificial intelligenceImage (mathematics)

Abstract

fetched live from OpenAlex

The detective quantum efficiency (DQE) is a metric widely used in radiography to quantify system performance and as a surrogate measure of patient "dose efficiency." It has been applied previously to fluoroscopic systems with the introduction of a temporal correction factor. Calculation of this correction factor relies on measurements of the temporal modulation transfer function (MTF). However, the temporal MTF is often exposure-rate dependent, violating a necessary Fourier linearity requirement. The authors show that a Fourier analysis is appropriate for fluoroscopic systems if a "small-signal" approach is used. Using a semitransparent edge, a lag-corrected DQE is described and measured for an x-ray image intensifier-based fluoroscopic system under continuous (non-pulsed) exposure conditions. It was found that results were equivalent for both rising and falling-edge profiles independent of edge attenuation when effective attenuation was in the range of 0.1-0.6. This suggests that this range is appropriate for measuring the small-signal temporal MTF. In general, lag was greatest at low exposure rates. It was also found that results obtained using a falling-edge profile with a radiopaque edge were equivalent to the small-signal results for the test system. If this result is found to be true generally, it removes the need for the small-signal approach. Lag-corrected DQE values were validated by comparison with radiographic DQE values obtained using very long exposures under the same conditions. Lag was observed to inflate DQE measurements by up to 50% when ignored.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.235
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207