MétaCan
Menu
Back to cohort
Record W1999101585 · doi:10.1118/1.3447722

Design of iterative ROI transmission tomography reconstruction procedures and image quality analysis

2010· article· en· W1999101585 on OpenAlexafffund
Benoît Hamelin, Yves Goussard, Jean‐Pierre Dussault, Guy Cloutier, Gilles Beaudoin, Gilles Soulez

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsCentre Hospitalier de l’Université de MontréalHôpital Notre-DameUniversité de SherbrookePolytechnique Montréal
FundersCanadian Institutes of Health Research
KeywordsImaging phantomIterative reconstructionRegion of interestImage qualityComputer visionComputer scienceArtificial intelligenceScannerIterative methodImage resolutionProjection (relational algebra)Reconstruction algorithmAlgorithmImage (mathematics)OpticsPhysics

Abstract

fetched live from OpenAlex

PURPOSE: An iterative edge-preserving CT reconstruction algorithm for high-resolution imaging of small regions of the field of view is investigated. It belongs to a family of region-of-interest reconstruction techniques in which a low-cost pilot reconstruction of the whole field of view is first performed and then used to deduce the contribution of the region of interest to the projection data. These projections are used for a high-resolution reconstruction of the region of interest (ROI) using a regularized iterative algorithm, resulting in significant computational savings. This paper examines how the technique by which the pilot reconstruction of the full field of view is obtained affects the total runtime and the image quality in the region of interest. METHODS: Previous contributions to the literature have each focused on a single approach for the pilot reconstruction. In this paper, two such approaches are compared: the filtered backprojection and a low-resolution regularized iterative reconstruction method. ROI reconstructions are compared in terms of image quality and computational cost over simulated and physical phantom (Catphan600) studies, in order to assess the compromises that most impact the quality of the ROI reconstruction. RESULTS: With the simulated phantom, new artifacts that appear in the ROI images are caused by significant errors in the pilot reconstruction. These errors include excessive coarseness of the pilot image grid and beam-hardening artifacts. With the Catphan600 phantom, differences in the imaging model of the scanner and that of the iterative reconstruction algorithm cause dark border artifacts in the ROI images. CONCLUSIONS: Inexpensive pilot reconstruction techniques (analytical algorithms, very-coarse-grid penalized likelihood) are practical choices in many common cases. However, they may yield background images altered by edge degradation or beam hardening, inducing projection inconsistency in the data used for ROI reconstruction. The ROI images thus have significant streak and speckle artifacts, which adversely affect the resolution-to-noise compromise. In these cases, edge-preserving penalized-likelihood methods on not-too-coarse image grids prove to be more robust and provide the best ROI image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.730
Threshold uncertainty score0.281

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.342
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207