MétaCan
Menu
Back to cohort
Record W2000431518 · doi:10.1111/acem.12210

Triple Rule-out Computed Tomographic Angiography for Chest Pain: A Diagnostic Systematic Review and Meta-Analysis

2013· review· en· W2000431518 on OpenAlexaffabout
David Ayaram, Fernanda Bellolio, M. Hassan Murad, Torrey A. Laack, Annie T. Sadosty, Patricia J. Erwin, Judd E. Hollander, Víctor M. Montori, Ian G. Stiell, Erik P. Hess

Bibliographic record

VenueAcademic Emergency Medicine · 2013
Typereview
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineComputed tomographic angiographyChest painMeta-analysisRadiologyComputed tomographicCoronary angiographyAngiographyComputed tomographyCardiologyInternal medicineMyocardial infarction

Abstract

fetched live from OpenAlex

OBJECTIVES: The objective was to compare the image quality, diagnostic accuracy, radiation exposure, and contrast volume of "triple rule-out" (TRO) computed tomography (CT) to other diagnostic modalities commonly used to evaluate patients with nontraumatic chest pain (dedicated coronary, pulmonary embolism [PE], and aortic dissection CT; invasive coronary angiography; and nuclear stress testing). METHODS: Four electronic databases were searched, along with reference lists and contacted content experts, for relevant studies from inception until October 2012. Eligible studies enrolled patients with nontraumatic chest pain, shortness of breath, suspected acute coronary syndrome (ACS), PE, or aortic dissection; used at least 64-slice CT technology; and compared TRO CT to another diagnostic modality. RESULTS: Eleven studies enrolling 3,539 patients (791 TRO and 2,748 non-TRO) were included (one randomized controlled trial and 10 observational). There was no significant difference in image quality between TRO and dedicated CT scans. TRO CT had the following pooled diagnostic accuracy estimates for coronary artery disease: sensitivity of 94.3% (95% confidence interval [CI] = 89.1% to 97.5%), specificity of 97.4% (95% CI = 96.1% to 98.4%), positive likelihood ratio (LR+) of 17.71 (95% CI = 3.92 to 79.96), and negative likelihood ratio (LR-) of 0.08 (95% CI = 0.02 to 0.27). There were insufficient numbers of patients with PE or aortic dissection to generate diagnostic accuracy estimates for these conditions. Use of TRO CT involved greater radiation exposure (mean difference [MD] = 4.84 mSv, 95% CI = 1.65 to 8.04 mSv) and contrast exposure (MD = 38.0 mL, 95% CI = 28.1 to 48.0 mL) compared to non-TRO CT patients. CONCLUSIONS: Triple rule-out CT is highly accurate for detecting coronary artery disease. Given the low (<1%) prevalence of PE and aortic dissection in the included studies, and the increased radiation and contrast exposure, there are insufficient data to recommend use of TRO CT in the diagnosis of these conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.034
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.017
Threshold uncertainty score0.073

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.034
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0170.029
Bibliometrics0.0060.007
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.124
GPT teacher head0.394
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations82
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueAcademic Emergency MedicineSame topicCardiac Imaging and DiagnosticsFrench-language works237,207