MétaCan
Menu
Back to cohort
Record W2000605388 · doi:10.1118/1.2244697

Sci‐Sat AM (2) Therapy‐01: A rotational total skin electron irradiation technique using a linear accelerator with a commercially available high dose rate total body electron mode

2006· article· en· W2000605388 on OpenAlexaff
Michael D. Evans, Jan Seuntjens, William Parker, Slobodan Dević, E. Poli, C Freeman, E. B. Podgoršak

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldMedicine
TopicNonmelanoma Skin Cancer Studies
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsLinear particle acceleratorIonization chamberDosimetryMonitor unitBremsstrahlungIrradiationBeam (structure)BetatronPercentage depth dose curveElectronCathode rayNuclear medicineDose profilePhysicsMaterials scienceIonizationAtomic physicsOpticsNuclear physicsMedicineIon

Abstract

fetched live from OpenAlex

We have transferred and modernized our 25‐year‐old rotational total skin electron irradiation (RTSEI) technique from a linac (Varian Clinac‐18) with a custom modified beam line to a linac (Varian 21EX) with a commercially available electron mode intended for total skin electron irradiation. The new technique uses a “high dose rate” mode and a “high dose per Monitor Unit” mode in conjunction with a custom‐made flattening filter to produce a uniform beam at an extended SSD of 378 cm. Reference dosimetry for the stationary and rotational electron fields was performed to allow delivery of the prescription dose using the linac's transmission ionization chamber. The accessory tray holds the custom‐made flattening filter and automatically selects the beam energy (6 MeV) and high dose rate (888 MU/min) while moving the collimators to the maximum 40 × 40 cm2 field size. Beam parameters are monitored using the record‐and‐verify (VARIS) system. Patients are treated on a rotating platform with a high dose rate electron beam having a zmax at the skin surface, an R50 at 15 mm and a bremsstrahlung contamination of the order of 3%. The nominal dose rate to water at zmax (surface) for the rotational technique was determined to be 24.1 cGy/1000 MU, and beam delivery is monitored with a secondary Farmer‐type ionization chamber located near the patient in the treatment field. Treatment times for a daily dose of 2.0 Gy are of the order of 9.5 minutes and to date we have treated 15 patients with this technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.029
Threshold uncertainty score0.098

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0290.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.284
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicNonmelanoma Skin Cancer StudiesFrench-language works237,207