MétaCan
Menu
Back to cohort
Record W2001159719 · doi:10.1159/000337259

Evaluation of Falls Risk in Community-Dwelling Older Adults Using Body-Worn Sensors

2012· article· en· W2001159719 on OpenAlexaff
Barry R. Greene, Emer P. Doheny, Cathal Walsh, Clodagh Cunningham, Lisa Crosby, Rose Anne Kenny

Bibliographic record

VenueGerontology · 2012
Typearticle
Languageen
FieldHealth Professions
TopicBalance, Gait, and Falls Prevention
Canadian institutionsTrinity College
Fundersnot available
KeywordsMedicinePoison controlBalance (ability)Injury preventionGaitTimed Up and Go testPhysical medicine and rehabilitationGerontologyPhysical therapyMedical emergency

Abstract

fetched live from OpenAlex

BACKGROUND: Falls are the most common cause of injury and hospitalization and one of the principal causes of death and disability in older adults worldwide. This study aimed to determine if a method based on body-worn sensor data can prospectively predict falls in community-dwelling older adults, and to compare its falls prediction performance to two standard methods on the same data set. METHODS: Data were acquired using body-worn sensors, mounted on the left and right shanks, from 226 community-dwelling older adults (mean age 71.5 ± 6.7 years, 164 female) to quantify gait and lower limb movement while performing the 'Timed Up and Go' (TUG) test in a geriatric research clinic. Participants were contacted by telephone 2 years following their initial assessment to determine if they had fallen. These outcome data were used to create statistical models to predict falls. RESULTS: Results obtained through cross-validation yielded a mean classification accuracy of 79.69% (mean 95% CI: 77.09-82.34) in prospectively identifying participants that fell during the follow-up period. Results were significantly (p < 0.0001) more accurate than those obtained for falls risk estimation using two standard measures of falls risk (manually timed TUG and the Berg balance score, which yielded mean classification accuracies of 59.43% (95% CI: 58.07-60.84) and 64.30% (95% CI: 62.56-66.09), respectively). CONCLUSION: Results suggest that the quantification of movement during the TUG test using body-worn sensors could lead to a robust method for assessing future falls risk.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.106
GPT teacher head0.427
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations96
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueGerontologySame topicBalance, Gait, and Falls PreventionFrench-language works237,207