MétaCan
Menu
Back to cohort
Record W2001353181 · doi:10.1109/iecon.2008.4758308

Voltage and frequency control with neutral current compensation in an isolated wind energy conversion system

2008· article· en· W2001353181 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicWind Turbine Control Systems
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsControl theory (sociology)Wind powerTransformerVoltage sourceComputer scienceElectric power systemElectrical engineeringAC powerVoltageEngineeringPhysicsPower (physics)

Abstract

fetched live from OpenAlex

This paper presents a voltage and frequency controller with neutral current compensation in an isolated wind energy conversion system employing a capacitor excited asynchronous generator (CEAG). In isolated applications, because of unavailability of the neutral point at the generator terminals, it is difficult to access the neutral wire from the source. In view of this, a transformer integrated with a voltage source converter (VSC) based voltage and frequency controller is used to provide the neutral terminal for the single phase consumer loads. A star delta transformer is used to provide the path for flow of the load neutral current. The complete standalone system is modeled and simulated for isolated wind energy conversion system in MATLAB using Simulink and power system blockset (PSB).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.798
Threshold uncertainty score0.584

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.175
Teacher spread0.167 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Quick stats

Citations8
Published2008
Admission routes1
Has abstractyes

Explore more

Same topicWind Turbine Control SystemsFrench-language works237,207